Automated image quality evaluation of structural brain MRI using an ensemble of deep learning networks
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: Deep learning (DL) is a promising methodology for automatic detection of abnormalities in brain MRI. Purpose: To automatically evaluate the quality of multicenter structural brain MRI images using an ensemble DL model based on deep convolutional neural networks (DCNNs). Study Type: Retrospective. Population: The study included 1064 brain images of autism patients and healthy controls from the Autism Brain Imaging Data Exchange (ABIDE) database. MRI data from 110 multiple sclerosis patients from the CombiRx study were included for independent testing. Sequence: T 1‐weighted MR brain images acquired at 3T. Assessment: The ABIDE data were separated into training (60%), validation (20%), and testing (20%) sets. The ensemble DL model combined the results from three cascaded networks trained separately on the three MRI image planes (axial, coronal, and sagittal). Each cascaded network consists of a DCNN followed by a fully connected network. The quality of image slices from each plane was evaluated by the DCNN and the resultant image scores were combined into a volumewise quality rating using the fully connected network. The DL predicted ratings were compared with manual quality evaluation by two experts. Statistical Tests: Receiver operating characteristic (ROC) curve, area under ROC curve (AUC), sensitivity, specificity, accuracy, and positive (PPV) and negative (NPV) predictive values. Results: The AUC, sensitivity, specificity, accuracy, PPV, and NPV for image quality evaluation of the ABIDE test set using the ensemble model were 0.90, 0.77, 0.85, 0.84, 0.42, and 0.96, respectively. On the CombiRx set the same model achieved performance of 0.71, 0.41, 0.84, 0.73, 0.48, and 0.80. Data Conclusion: This study demonstrated the high accuracy of DL in evaluating image quality of structural brain MRI in multicenter studies. Level of Evidence: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1260–1267.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Di Martino, A., Yan, C.-G., Li, Q., Denio, E., Castellanos, F. X., Alaerts, K., Anderson, J. S., Assaf, M., Bookheimer, S. Y., Dapretto, M., et al. (2014) · Molecular Psychiatry · doi:10.1038/mp.2013.78 · Cited by 2,780 · cited 2×
“The publicly available Autism Brain Imaging Data Exchange (ABIDE) dataset contains 1064 structural brain image volumes acquired on 1112 subjects.(17) The ABIDE study included individuals with and without autism spectrum disorder, aged between 7 to 64 years.”
MRIQC: Advancing the automatic prediction of image quality in MRI from unseen sites
Esteban, O., Birman, D., Schaer, M., Koyejo, O. O., Poldrack, R. A., & Gorgolewski, K. J. (2017) · PLOS ONE · doi:10.1371/journal.pone.0184661 · Cited by 920
Head motion during MRI acquisition reduces gray matter volume and thickness estimates
Reuter, M., Tisdall, M. D., Qureshi, A., Buckner, R. L., van der Kouwe, A. J. W., & Fischl, B. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.006 · Cited by 457
Alexander-Bloch, A., Clasen, L., Stockman, M., Ronan, L., Lalonde, F., Giedd, J., & Raznahan, A. (2016) · Human Brain Mapping · doi:10.1002/hbm.23180 · Cited by 178 · cited 1×
“Therefore, evaluation of image quality is necessary for excluding poor-quality images that could compromise diagnostic confidence and affect downstream analysis.(2,3) Visual inspection of MR images is impractical for large datasets such as in multicenter studies.”
BackgroundAutomated reference-free detection of motion artifacts in magnetic resonance images
Küstner, T., Liebgott, A., Mauch, L., Martirosian, P., Bamberg, F., Nikolaou, K., Yang, B., Schick, F., & Gatidis, S. (2018) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-017-0650-z · Cited by 102 · cited 4×
“However, because 2D scans still present most of the clinical MRI, it is important to investigate application of implemented DL solutions to the evaluation of the quality of 2D images.”
MethodInfluential
Cited by
Khodatars, M., Shoeibi, A., Sadeghi, D., Ghaasemi, N., Jafari, M., Moridian, P., Khadem, A., Alizadehsani, R., Zare, A., Kong, Y., et al. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104949 · Cited by 270
Shoeibi, A., Khodatars, M., Jafari, M., Moridian, P., Rezaei, M., Alizadehsani, R., Khozeimeh, F., Gorriz, J. M., Heras, J., Panahiazar, M., et al. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104697 · Cited by 187
“Different Methods 3D U-Net -- -- DSC=68.4 Narayana [157] Tissue Classification CombiRx MRI 1008 MS -- MRIAP Pipeline, DA Multi-Class U-Net Keras, TensorFlow -- WM-DSC=94 GM-DSC=94 CSF-DSC=97 Lesion-DSC= 85 Hu [160] Lesion Segmentation ISBI 2015 MRI 19 MS -- Data Enhancement 3D Attention Context U-Net (ACU-Net) Keras,…”
BackgroundMethodInfluentialArtificial intelligence in emergency radiology: A review of applications and possibilities
Katzman, B. D., van der Pol, C. B., Soyer, P., & Patlas, M. N. (2023) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2022.07.005 · Cited by 97
Chen, Z., Liu, X., Yang, Q., Wang, Y.-J., Miao, K., Gong, Z., Yu, Y., Leonov, A., Liu, C., Feng, Z., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.1671 · Cited by 43
Chen, Z., Hu, B., Liu, X., Becker, B., Eickhoff, S. B., Miao, K., Gu, X., Tang, Y., Dai, X., Li, C., et al. (2023) · BMC Medicine · doi:10.1186/s12916-023-02941-4 · Cited by 35
Metadata
- Authors
- Sujit, S. J., Coronado, I., Kamali, A., Narayana, P. A., & Gabr, R. E.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2019-02-27
- Volume
- 50
- Issue
- 4
- Pages
- 1260-1267
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2916800028
- Cited by
- 68
- References
- 6
- FWCI
- 5.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated image quality evaluation of structural brain MRI using an ensemble of deep learning networks. https://app.cochat.ai/papers/10.1002/jmri.26693
- The paper
- Sujit, S. J., Coronado, I., Kamali, A., Narayana, P. A., & Gabr, R. E. (2019). Automated image quality evaluation of structural brain MRI using an ensemble of deep learning networks. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.26693
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.