Mass spectrometric characterization of covalent modification of human serum albumin by 4‐hydroxy‐trans‐2‐nonenal
The DOI matches its Crossref record.
Abstract
Several pieces of evidence indicate that albumin modified by HNE is a promising biomarker of systemic oxidative stress and that HNE‐modified albumin may contribute to the immune reactions triggered by lipid peroxidation‐derived antigens. In this study, we found by HPLC analysis that HNE is rapidly quenched by human serum albumin (HSA) because of the covalent adduction to the different accessible nucleophilic residues of the protein, as demonstrated by electrospray ionization mass spectrometry (ESI‐MS) direct infusion experiments (one to nine HNE adducts, depending on the molar ratio used, from 1 : 0.25 to 1 : 5 HSA : HNE). An LC‐ESI‐MS/MS approach was then applied to enzymatically digested HNE‐modified albumin, which permitted the identification of 11 different HNE adducts, 8 Michael adducts (MA) and 3 Schiff bases (SB), involving nine nucleophilic sites, namely: His67 (MA), His146 (MA), His242 (MA), His288 (MA), His510 (MA), Lys 195 (SB), Lys 199 (MA, SB), Lys525 (MA, SB) and Cys34 (MA). The most reactive HNE‐adduction site was found to be Cys34 (MA) followed by Lys199, which primarily reacts through the formation of a Schiff base, and His146, giving the corresponding HNE Michael adduct. These albumin modifications are suitable tags of HNE‐adducted albumin and could be useful biomarkers of oxidative and carbonylation damage in humans. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Physiology and Pathophysiology of Carnosine
Boldyrev, A. A., Aldini, G., & Derave, W. (2013) · Physiological Reviews · doi:10.1152/physrev.00039.2012 · Cited by 1,114
Self-citationProtein carbonylation as a major hallmark of oxidative damage: Update of analytical strategies
Fedorova, M., Bollineni, R. C., & Hoffmann, R. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21381 · Cited by 516
Rabbani, G., & Ahn, S. N. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2018.11.053 · Cited by 505
Molecular Mechanisms of Aldehyde Toxicity: A Chemical Perspective
LoPachin, R. M., & Gavin, T. (2014) · Chemical Research in Toxicology · doi:10.1021/tx5001046 · Cited by 495
The glycation of albumin: Structural and functional impacts
Rondeau, P., & Bourdon, E. (2011) · Biochimie · doi:10.1016/j.biochi.2010.12.003 · Cited by 433
“Noteworthy enough, Cys 34 and Lys199 in albumin were shown to be the most reactive HNE-adduction sites [33].”
Background
Metadata
- Authors
- Aldini, G., Gamberoni, L., Orioli, M., Beretta, G., Regazzoni, L., Maffei Facino, R., & Carini, M.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2006-08-03
- Volume
- 41
- Issue
- 9
- Pages
- 1149-1161
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W2164965557
- Cited by
- 115
- References
- 0
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass spectrometric characterization of covalent modification of human serum albumin by 4‐hydroxy‐trans‐2‐nonenal. https://app.cochat.ai/papers/10.1002/jms.1067
- The paper
- Aldini, G., Gamberoni, L., Orioli, M., Beretta, G., Regazzoni, L., Maffei Facino, R., & Carini, M. (2006). Mass spectrometric characterization of covalent modification of human serum albumin by 4‐hydroxy‐trans‐2‐nonenal. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.1067
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.