CoChat

Detection and identification of arginine modifications on methylglyoxal‐modified ribonuclease by mass spectrometric analysis

Brock, Jonathan W. C., Cotham, William E., Thorpe, Suzanne R., Baynes, John W, Ames, Jennifer M. · 2007 · Journal of Mass Spectrometry
Cited by 40

The DOI matches its Crossref record.

Abstract

Analysis of the broad range of trace chemical modifications of proteins in biological samples is a significant challenge for modern mass spectrometry. Modification at lysine and arginine residues, in particular, causes resistance to digestion by trypsin, producing large tryptic peptides that are not readily sequenced by mass spectrometry. In this work, we describe the analysis of ribonuclease (RNase) modified by methylglyoxal (MGO) under physiological conditions. For detection of modifications, we use comparative analysis of the single combined spectra extracted from the full‐scan MS data of the tryptic digests from native and modified proteins. This approach revealed 11 ions unique to MGO‐modified RNase, including a 32‐amino acid peptide containing a modified Arg‐85 residue. Sequential digestion of MGO‐modified RNase by endoproteinase Glu‐C and trypsin was required to obtain peptides that were amenable to sequencing analysis. Arg‐39 was identified as the main site of modification (35% modification) on MGO‐modified Rnase, and the dihydroxyimidazolidine and hydroimidazolone derivatives were the main adducts formed, with minor amounts of the tetrahydropyrimidine and argpyrimidine derivatives. For identification of these products, we used variations in source voltage and collision energy to obtain the dehydration and decarboxylation products of the tetrahydropyrimidine‐containing peptides and dehydration of the dihydroxyimidazoline‐containing peptides. The resultant spectra were dependent on the cone voltage and collision energy, and analysis of spectra at various settings permitted structural assignments. These studies illustrate the usefulness of single combined mass spectra extracted from full‐scan data and variations in source and collision cell voltages for detection and structural characterization of chemical adducts on proteins. Copyright © 2006 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jms.1144

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 40

Metadata

Authors
Brock, J. W. C., Cotham, W. E., Thorpe, S. R., Baynes, J. W., & Ames, J. M.
Venue
Journal of Mass Spectrometry
Publisher
Wiley
Published
2006-12-04
Volume
42
Issue
1
Pages
89-100
ISSN
  • 1076-5174 (ISSN-L)
  • 1096-9888
OpenAlex
W1983241921
Cited by
40
References
0
FWCI
0.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection and identification of arginine modifications on methylglyoxal‐modified ribonuclease by mass spectrometric analysis. https://app.cochat.ai/papers/10.1002/jms.1144
The paper
Brock, J. W. C., Cotham, W. E., Thorpe, S. R., Baynes, J. W., & Ames, J. M. (2007). Detection and identification of arginine modifications on methylglyoxal‐modified ribonuclease by mass spectrometric analysis. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.1144

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.