Hollow‐fiber liquid‐phase microextraction prior to low‐temperature electrothermal vaporization ICP‐MS for trace element analysis in environmental and biological samples
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A new method of hollow‐fiber liquid‐phase microextraction (HF‐LPME) prior to electrothermal vaporization (ETV) inductively coupled plasma mass spectrometry (ICP‐MS) determination of trace Cu, Zn, Pd, Cd, Hg, Pb and Bi, based on gaseous compounds introduction into the plasma as their diethyldithiocarbmate (DDTC) chelates, was developed. The use of the reagent DDTC as chemical modifier could not only enhance the analytical signals, but also decrease the vaporization temperature. At a temperature of 1300 °C, trace Cu, Zn, Pd, Cd, Hg, Pb and Bi can be vaporized completely into the ICP. The factors affecting the formation of the chelates and their vaporization behaviors were investigated in detail, and the microextraction conditions were optimized. Under the optimized conditions, the detection limits of the proposed method were 12.4, 28.7, 7.9, 4.5, 3.3, 4.8 and 1.6 pg ml−1 for Cu, Zn, Pd, Cd, Hg, Pb and Bi, respectively. Enrichment factors of 305, 284, 24, 29, 20, 73 and 43 could be achieved within 15 min of extraction time, and the relative standard deviations (RSDs) for the seven determinations of 0.5 ng ml−1 of target analytes were 8.8, 6.9, 7.1, 9.4, 10.2, 6.1 and 10.8%, respectively. The newly developed method has been applied to the determination of trace Cu, Zn, Pd, Cd, Hg, Pb and Bi in environmental water and human serum samples, and the recoveries for the spiked samples were in the range of 88–116%. In order to validate this method, two certified reference materials, GBW08501 peach leaves and GBW(E)080040 seawater, were analyzed, and the determined values were in good agreement with the certified values. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Cited by
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2009) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.10.042 · Cited by 414
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Liquid-Phase Microextraction in Bioanalytical Sample Preparation
Lucena, R., Cruz-Vera, M., Cárdenas, S., & Valcárcel, M. (2009) · Bioanalysis · doi:10.4155/bio.09.16 · Cited by 55
Rivas, R. E., López-García, I., & Hernández-Córdoba, M. (2010) · Analytical Methods · doi:10.1039/b9ay00237e · Cited by 47
Alavi, L., Seidi, S., Jabbari, A., & Baheri, T. (2017) · New Journal of Chemistry · doi:10.1039/c7nj00922d · Cited by 37
Herce-Sesa, B., López-López, J. A., & Moreno, C. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2017.11.004 · Cited by 26
Metadata
- Authors
- Xia, L., Wu, Y., & Hu, B.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2007-05-18
- Volume
- 42
- Issue
- 6
- Pages
- 803-810
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W2128888093
- Cited by
- 93
- References
- 2
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.