The DOI matches its Crossref record.
Petroleomics: advanced molecular probe for petroleum heavy ends
Abstract
To look into complex mixtures of petroleum heavy ends at the molecular level, ultra high‐resolution mass spectrometry, i.e. resolving power > 50 000, is needed to resolve overlapping components for accurate determination of molecular composition of individual components. Recent progress in Fourier transform ion cyclotron resonance mass spectrometry (FT‐ICR MS) incorporated with soft ionization techniques adaptable to liquid chromatography enables analysis of petroleum high ends, i.e., heavy oils, residua and asphaltenes. FT‐ICR MS at the Future Fuels Institute of Florida State University and the National High Magnetic Field Laboratory (NHMFL) routinely provides 1 000 000 resolving power at 400 Da, with root mean square (rms) mass measurement accuracy between 30 and 500 ppb for 5000–30 000 identified species in a single mass spectrum. Phase correction of the detected ion signal increases resolving power 40–100%, improving mass accuracy up to twofold. Overlapping ionic species that differ in mass by as little as one electron mass (548 µDa) can be resolved. A database of more than 100 000 components of different elemental composition has been generated at NHMFL. Copyright © 2011 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chemicals from Direct Coal Liquefaction
Mochida, I., Okuma, O., & Yoon, S.-H. (2014) · Chemical Reviews · doi:10.1021/cr4002885 · Cited by 269
Simple, Expendable, 3D-Printed Microfluidic Systems for Sample Preparation of Petroleum
Kataoka, É. M., Murer, R. C., Santos, J. M., Carvalho, R. M., Eberlin, M. N., Augusto, F., Poppi, R. J., Gobbi, A. L., & Hantao, L. W. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04413 · Cited by 63
Metadata
- Authors
- Hsu, C. S., Hendrickson, C. L., Rodgers, R. P., McKenna, A. M., & Marshall, A. G.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2011-03-24
- Volume
- 46
- Issue
- 4
- Pages
- 337-343
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W2007185001
- Cited by
- 197
- References
- 0
- FWCI
- 19.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.