The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Shotgun lipidomics on a LTQ Orbitrap mass spectrometer by successive switching between acquisition polarity modes
Abstract
Top–down shotgun lipidomics relies on direct infusion of total lipid extracts into a high‐resolution tandem mass spectrometer and implies that individual lipids are recognized by their accurately determined m/z. Lipid ionization efficiency and detection specificity strongly depend on the acquisition polarity, and therefore it is beneficial to analyze lipid mixtures in both positive and negative modes. Hybrid LTQ Orbitrap mass spectrometers are widely applied in top–down lipidomics; however, rapid polarity switching was previously unfeasible because of the severe and immediate degradation of mass accuracy. Here, we report on a method to rapidly acquire high‐resolution spectra in both polarity modes with sub‐ppm mass accuracy and demonstrate that it not only simplifies and accelerates shotgun lipidomics analyses but also improves the lipidome coverage because more lipid classes and more individual species within each class are recognized. In this way, shotgun analysis of total lipid extracts of human blood plasma enabled to quantify 222 species from 15 major lipid classes within 7 min acquisition cycle. Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lipidomics reveals a remarkable diversity of lipids in human plasma
Quehenberger, O., Armando, A. M., Brown, A. H., Milne, S. B., Myers, D. S., Merrill, A. H., Bandyopadhyay, S., Jones, K. N., Kelly, S., Shaner, R. L., et al. (2010) · Journal of Lipid Research · doi:10.1194/jlr.m009449 · Cited by 1,341
Han, X., & Gross, R. W. (2003) · Journal of Lipid Research · doi:10.1194/jlr.r300004-jlr200 · Cited by 914
Cited by
Shorthand notation for lipid structures derived from mass spectrometry
Liebisch, G., Vizcaíno, J. A., Köfeler, H., Trötzmüller, M., Griffiths, W. J., Schmitz, G., Spener, F., & Wakelam, M. J. O. (2013) · Journal of Lipid Research · doi:10.1194/jlr.m033506 · Cited by 833
Evolution of Orbitrap Mass Spectrometry Instrumentation
Eliuk, S., & Makarov, A. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040325 · Cited by 456
Recent developments in liquid chromatography–mass spectrometry and related techniques
Holčapek, M., Jirásko, R., & Lísa, M. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.08.072 · Cited by 330
Surma, M. A., Herzog, R., Vasilj, A., Klose, C., Christinat, N., Morin‐Rivron, D., Simons, K., Masoodi, M., & Sampaio, J. L. (2015) · European Journal of Lipid Science and Technology · doi:10.1002/ejlt.201500145 · Cited by 283
Self-citationEffects of diet and development on the Drosophila lipidome
Carvalho, M., Sampaio, J. L., Palm, W., Brankatschk, M., Eaton, S., & Shevchenko, A. (2012) · Molecular Systems Biology · doi:10.1038/msb.2012.29 · Cited by 275
Self-citation
Metadata
- Authors
- Schuhmann, K., Almeida, R., Baumert, M., Herzog, R., Bornstein, S. R., & Shevchenko, A.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2012-01
- Volume
- 47
- Issue
- 1
- Pages
- 96-104
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W1569454591
- Cited by
- 207
- References
- 2
- FWCI
- 9.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.