Mass spectrometric characterization of lipid‐modified peptides for the analysis of acylated proteins
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The analysis of acylated proteins by mass spectrometry (MS) has largely been overshadowed in proteomics by the analysis of glycosylated and phosphorylated proteins; however, lipid modifications on proteins are proving to be of increasing importance in biomedical research. In order to identify the marker ions and/or neutral loss fragments that are produced upon collision‐induced dissociation, providing a means to identify the common lipid modifications on proteins, peptides containing an N‐terminally myristoylated glycine, a palmitoylated cysteine and a farnesylated cysteine were chemically synthesized. Matrix‐assisted laser desorption/ionization time‐of‐flight time‐of‐flight (MALDI‐TOF‐TOF), electrospray ionization quadrupole time‐of‐flight (ESI Q‐TOF), and electrospray ionization hybrid triple‐quadrupole/linear ion trap (ESI QqQ LIT) mass spectrometers were used for the analysis. The peptide containing the N‐terminally myristoylated glycine, upon CID, produced the characteristic fragments a 1 (240.4 Th) and b 1 (268.4 Th) ions as well as a low‐intensity neutral loss of 210 Da (C 14 H 26 O). The peptides containing a farnesylated cysteine residue fragmented to produce a marker ion at a m/z of 205 Th (C 15 H 25) as well as other intense farnesyl fragment ions, and a neutral loss of 204 Da (C 15 H 24). The peptides containing a palmitoylated cysteine moiety generated neutral losses of 238 Da (C 16 H 30 O) and 272 Da (C 16 H 32 OS); however, no marker ions were produced. The neutral losses were more prominent in the MALDI‐TOF‐TOF spectra, whereas the marker ions were more abundant in the ESI QqQ LIT and Q‐TOF mass spectra. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Göttlinger, H. G., Sodroski, J. G., & Haseltine, W. A. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.15.5781 · Cited by 841
Anderegg, R. J., Betz, R., Carr, S. A., Crabb, J. W., & Duntze, W. (1988) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)81351-0 · Cited by 370
Zheng, J., Knighton, D. R., Taylor, S. S., Xuong, N., Sowadski, J. M., & Eyck, L. F. T. (1993) · Protein Science · doi:10.1002/pro.5560021003 · Cited by 281
Differential membrane binding of the human immunodeficiency virus type 1 matrix protein
Zhou, W., & Resh, M. D. (1996) · Journal of Virology · doi:10.1128/jvi.70.12.8540-8548.1996 · Cited by 226
Cited by
Larsen, M. R., Trelle, M. B., Thingholm, T. E., & Jensen, O. N. (2006) · BioTechniques · doi:10.2144/000112201 · Cited by 251
Fert-Bober, J., Murray, C. I., Parker, S. J., & Van Eyk, J. E. (2018) · Circulation Research · doi:10.1161/circresaha.118.310966 · Cited by 45
Hoffman, M. D., Walsh, G. M., Rogalski, J. C., & Kast, J. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800230-mcp200 · Cited by 41
Self-citationAn Acyl-covalent Enzyme Intermediate of Lecithin:Retinol Acyltransferase*
Golczak, M., & Palczewski, K. (2010) · Journal of Biological Chemistry · doi:10.1074/jbc.m110.152314 · Cited by 27
Metadata
- Authors
- Hoffman, M. D., & Kast, J.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2006-01-18
- Volume
- 41
- Issue
- 2
- Pages
- 229-241
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W1972063169
- Cited by
- 46
- References
- 4
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.