The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Metal ion release from titanium‐based prosthetic segmental replacements of long bones in baboons: A long‐term study
Abstract
Forty‐five baboons that had received titanium‐based fiber metal composite segmental bone replacements were studied along with 13 controls without implants. Thirty‐eight baboons with implants were sacrificed, and titanium, aluminum, and vanadium levels were assayed in homogenized lung, kidney, spleen, liver, adjacent muscle, and regional lymph nodes. In seven living baboons with implants, blood and urine samples were obtained for trace metal analysis as well as for biochemical and hematological profiles. In the 38 sacrificed baboons with implants, increased titanium levels were noted in the lungs, spleen, adjacent muscle (quadriceps, soleus, and triceps), and regional lymph nodes (inguinal, axillary, and popliteal) in comparison to those of six sacrificed controls without implants. In addition, vanadium was significantly elevated in the lungs of some animals, while aluminum increases were noted in adjacent muscle (quadriceps, soleus, and triceps), lung, and regional lymph nodes (inguinal, axillary, and popliteal). In the seven living baboons with implants, a sixfold increase (p < 0.0005) in the urine titanium level was noted in comparison to that of seven living controls without implants. Additionally, elevated aluminum levels were found in the serum (p < 0.0005) of the group with implants. Biochemical and hematological studies did not indicate statistically significant differences in serum electrolytes, in liver and renal function tests, or in complete blood counts between the seven living baboons with implants and their controls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berger, S. L., & Birkenmeier, C. S. (1979) · Biochemistry · doi:10.1021/bi00590a018 · Cited by 443
Cited by
Metal ion release from metal implants
Hanawa, T. (2004) · Materials Science and Engineering: C · doi:10.1016/j.msec.2004.08.018 · Cited by 528
Biomedical Applications of Titanium Alloys: A Comprehensive Review
Marin, E., & Lanzutti, A. (2023) · Materials · doi:10.3390/ma17010114 · Cited by 489
Teeth and bones: applications of surface science to dental materials and related biomaterials
Jones, F. (2001) · Surface Science Reports · doi:10.1016/s0167-5729(00)00011-x · Cited by 399
Peri-implant osteogenesis in health and osteoporosis
Marco, F., Milena, F., Gianluca, G., & Vittoria, O. (2005) · Micron · doi:10.1016/j.micron.2005.07.008 · Cited by 304
Can degradation products released from dental implants affect peri‐implant tissues?
Noronha Oliveira, M., Schunemann, W. V. H., Mathew, M. T., Henriques, B., Magini, R. S., Teughels, W., & Souza, J. C. M. (2018) · Journal of Periodontal Research · doi:10.1111/jre.12479 · Cited by 291
Metadata
- Authors
- Woodman, J. L., Jacobs, J. J., Galante, J. O., & Urban, R. M.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1983-01
- Volume
- 1
- Issue
- 4
- Pages
- 421-430
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2164526852
- Cited by
- 237
- References
- 1
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metal ion release from titanium‐based prosthetic segmental replacements of long bones in baboons: A long‐term study. https://app.cochat.ai/papers/10.1002/jor.1100010411
- The paper
- Woodman, J. L., Jacobs, J. J., Galante, J. O., & Urban, R. M. (1983). Metal ion release from titanium‐based prosthetic segmental replacements of long bones in baboons: A long‐term study. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100010411
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.