Less rigid internal fixation plates: Historical perspectives and new concepts
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
In the application of “rigid” plates for diaphyseal fractures, lack of callus healing and overprotection of the underlying bone are viewed by many investigators as undesirable consequences. Potential solutions offered to overcome these deficiencies include modification of the timing of plate removal, use of biologically degradable materials for plates so that stressshielding can be minimized, and use of less rigid plate fixation systems. This study emphasizes the selection of appropriate design criteria for less rigid plate‐fixation systems. To accomplish this goal, the axial, bending, and torsional stiffness parameters are considered in place of the oversimplified terms such as “flexible plate” or “elastic fixation.” With the aid of finite element modeling and simplified bench experiments, we performed parametric studies and singled out the plate axial stiffness as the dominant factor in altering the bone stresses. As a result, we designed two experimental plates, one a thin Ti‐6Al‐4V (titanium with 6% aluminum and 4% vanadium) alloy plate with low stiffness in axial and bending directions, and the other a tubular stainless steel plate with low stiffness in the axial direction but moderate stiffness in bending and torsional directions. The low‐stiffness Ti‐6Al‐4V alloy plate was first tested in a demanding bilateral canine midshalt osteotomy, and proved to be inadequate. Both experimental plates were successful in the unilateral osteotomies, with the tubular plate yielding the best results. After 6 months of plating, the bones beneath the tubular plate had superior mechanical and structural properties as compared to those of the control “rigid” stainless steel and the Ti‐6Al‐4V alloy plates. Application of this plate prolonged for 9 months did not cause reduction in bone properties and strength. The success of the tubular plate is due to its moderate bending and torsional stiffnesses, which provide adequate fixation to achieve callus union, while its low axial stiffness permits the underlying bone to share the physiological stresses needed for bone remodeling. These drastic changes in mechanical demands on the internal fixation plate during the early healing phase and the postunion remodeling phase are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The biology of fracture healing in long bones
McKibbin, B. (1978) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.60b2.350882 · Cited by 1,180
Physical and biological aspects of fracture healing with special reference to internal fixation.
Sm, P. (1979) · PubMed · Cited by 678
Koch, J. C. (1917) · American Journal of Anatomy · doi:10.1002/aja.1000210202 · Cited by 626
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Tonino, A., Davidson, C., Klopper, P., & Linclau, L. (1976) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.58b1.1270486 · Cited by 338
Current concepts of internal fixation of fractures
Tubbs, N. (1981) · Injury · doi:10.1016/0020-1383(81)90078-4 · Cited by 326
Bone Structure Changes in the Dog Under Rigid Internal Fixation
Uhthoff, H. K., & Dubuc, F. L. (1971) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197111000-00026 · Cited by 281
The ultimate properties of bone tissue: The effects of yielding
Burstein, A. H., Currey, J. D., Frankel, V. H., & Reilly, D. T. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90017-6 · Cited by 255
Moyen, B., Lahey, P. J., Weinberg, E., & Harris, W. H. (1978) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197860070-00012 · Cited by 148
Akeson, W. H., Woo, S. L., Coutts, R. D., Matthews, J. V., Gonsalves, M., & Amiel, D. (1975) · Calcified Tissue International · doi:10.1007/bf02563988 · Cited by 108
Self-citationEffect of Rigid Plate Fixation on Structure and Mineral Content of Cortical Bone
Paavolainen, P., Karaharju, E., SLÄTIS, P., Ahonen, J., & Holmström, T. (1978) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197810000-00044 · Cited by 107
Stress fields in the unplated and plated canine femur calculated from in vivo strain measurements
Carter, D. R. P., Vasu, R., Spengler, D. M., & Dueland, R. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90081-6 · Cited by 92
Sarmiento, A., Mullis, D. L., Latta, L., Tarr, R. R., & ALVAREZ, R. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198006000-00035 · Cited by 57
Eggers, G. W. N. (1948) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-194830010-00006 · Cited by 52
The Plated Femur: Relationships Between the Changes in Bone Stresses and Bone Loss
Carter, D. R., Vasu, R., & Harris, W. H. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678109050099 · Cited by 33
Cited by
Delayed union and nonunions: Epidemiology, clinical issues, and financial aspects
Hak, D. J., Fitzpatrick, D., Bishop, J. A., Marsh, J. L., Tilp, S., Schnettler, R., Simpson, H., & Alt, V. (2014) · Injury · doi:10.1016/j.injury.2014.04.002 · Cited by 647
Biodegradable bone implants in orthopedic applications: a review
Chandra, G., & Pandey, A. (2020) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2020.02.003 · Cited by 190
A Review on Biomaterials for Orthopaedic Surgery and Traumatology: From Past to Present
Szczęsny, G., Kopec, M., Politis, D. J., Kowalewski, Z. L., Łazarski, A., & Szolc, T. (2022) · Materials · doi:10.3390/ma15103622 · Cited by 172
“Nowadays, titanium alloys have been widely used to fabricate trauma and orthopaedic implants [22,23] due to increased biocompatibility, lack of toxicity, osseointegration, high tensile strength to density ratio, and corrosion resistance.”
BackgroundThe investigation of bone fracture healing under intramembranous and endochondral ossification
Ghimire, S., Miramini, S., Edwards, G., Rotne, R., Xu, J., Ebeling, P., & Zhang, L. (2021) · Bone Reports · doi:10.1016/j.bonr.2020.100740 · Cited by 83
Metadata
- Authors
- Woo, S. L., Lothringer, K. S., Akeson, W. H., Coutts, R. D., Woo, Y. K., Simon, B. R., & Gomez, M. A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1983-01
- Volume
- 1
- Issue
- 4
- Pages
- 431-449
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2035413643
- Cited by
- 158
- References
- 15
- FWCI
- 0.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.