The DOI matches its Crossref record.
Three‐dimensional load‐displacement curves due to froces on the cervical spine
Abstract
Load‐displacement curves were measured for six types of pure force loading of the cervical spine specimens obtained from fresh human cadavers. A new measuring and mounting technique was developed that yielded data for all of the functional spinal units for each specimen tested. All five of the coupled, as well as the main, load‐displacement curves were studied. For anterior and posterior shear loadings, the main resulting motions were translation in that direction (1.6 ± 0.3 and 1.9 ± 0.3 mm), and the major coupled motions were flexion and extension (3.6° ± 1.2° and 6.3° ± 1.2°). The main motions with right and left lateral shear loadings were translations laterally (1.4 ± 0.3 and 1.6 ± 0.3 mm), and the major coupled motions were axial rotations (1.5° ± 0.6° and 2.3° ± 0.6°) and not lateral bending. For compression and distraction loadings, the main motions were translations in that direction (0.7 ± 0.3 and 1.1 ± 0.3 mm), and the major coupled motions were flexion and extension (2.0° ± 1.0° and 2.8° ± 1.0°) and lateral bending (1.4° ± 0.3° and 1.9° ± 0.3°). The neutral zones for anterior and posterior shear forces were 1.6 ± 0.2 mm of translation and 5.8° ± 1.3° of rotation, for lateral shear force 1.4 ± 0.3 mm and 2.0° ± 0.5°, and for compression/distraction 0.6 ± 0.1 mm and 2.8° ± 0.9°.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Panjabi, M. M., Crisco, J. J., Vasavada, A., Oda, T., Cholewicki, J., Nibu, K., & Shin, E. (2001) · Spine · doi:10.1097/00007632-200112150-00012 · Cited by 581
Self-citationLoad-displacement properties of lower cervical spine motion segments
Moroney, S. P., Schultz, A. B., Miller, J. A. A., & Andersson, G. B. J. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90285-0 · Cited by 459
Moment-rotation relationships of the ligamentous occipito-atlanto-axial complex
Goel, V. K., Clark, C. R., Gallaes, K., & Liu, Y. K. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90204-7 · Cited by 263
Geere, J.-A., Bartram, J., Bates, L., Danquah, L., Evans, B., Fisher, M. B., Groce, N., Majuru, B., Mokoena, M. M., Mukhola, M. S., et al. (2018) · Journal of Global Health · doi:10.7189/jogh.08.010406 · Cited by 111
Metadata
- Authors
- Panjabi, M. M., Summers, D. J., Pelker, R. R., Videman, T., Friedlaender, G. E., & Southwick, W. O.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1986-01
- Volume
- 4
- Issue
- 2
- Pages
- 152-161
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2034002968
- Cited by
- 170
- References
- 0
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three‐dimensional load‐displacement curves due to froces on the cervical spine. https://app.cochat.ai/papers/10.1002/jor.1100040203
- The paper
- Panjabi, M. M., Summers, D. J., Pelker, R. R., Videman, T., Friedlaender, G. E., & Southwick, W. O. (1986). Three‐dimensional load‐displacement curves due to froces on the cervical spine. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100040203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.