The DOI matches its Crossref record.
Cobalt, chromium, and nickel concentrations in body fluids of patients with porous‐coated knee or hip prostheses
Abstract
Co, Cr, and Ni concentrations were determined by electrothermal atomic absorption spectrophotometry in serum and urine specimens collected from a group of 28 patients at intervals of from 1 day to 2.5 years after total knee or hip arthroplasty with porous‐coated prostheses fabricated of Co‐Cr alloy (ASTM F‐75‐82). Two control groups were also tested: (a) 42 healthy adults and (b) 16 orthopaedic patients after total knee or hip arthroplasty with porous‐coated prostheses fabricated predominantly of Ti‐Al‐V alloy (ASTM F‐136‐84). All prostheses contained polyethylene components to avoid metal‐to‐metal contact. Mean Co concentrations in serum and urine were slightly increased in patients with Co‐Cr knee implants at 6–120 weeks after surgery, compared with (a) preoperative values, (b) corresponding values in patients with Co‐Cr hip implants, and (c) corresponding values in control patients with Ti‐Al‐V knee and hip prostheses. Substantially increased Co levels were observed in serum and urine of two patients at 7 weeks and 22 months postarthroplasty, associated with loosening of the prostheses; one of the patients also had elevated Cr levels in serum and urine. Although ASTM F‐75‐82 and F‐136‐84 alloys contain very little Ni (<1.0 and <0.2% Ni, respectively, by wt), mean Ni concentrations in serum and urine were greatly increased at 1–2 days after implantation of Ti‐Al‐V and Co‐Cr prostheses, diminishing by 2 weeks. The postoperative hypernickelemia and nickeluresis may reflect contamination of the operative field with Ni‐containing particles from the drills, cutting jigs, and drilling jigs, or it may represent a previously unrecognized pathophysiological response to surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cobalt toxicity in humans—A review of the potential sources and systemic health effects
Leyssens, L., Vinck, B., Van Der Straeten, C., Wuyts, F., & Maes, L. (2017) · Toxicology · doi:10.1016/j.tox.2017.05.015 · Cited by 1,045
Comparison of metal release from various metallic biomaterials in vitro
Okazaki, Y., & Gotoh, E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.005 · Cited by 862
URBAN, R. M., JACOBS, J. J., TOMLINSON, M. J., GAVRILOVIC, J., BLACK, J., & PEOC'H, M. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200004000-00002 · Cited by 787
Widespread dissemination of metal debris from implants
Case, C., Langkamer, V., James, C., Palmer, M., Kemp, A., Heap, P., & Solomon, L. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b5.8083255 · Cited by 444
Doorn, P. F., Campbell, P. A., Worrall, J., Benya, P. D., McKellop, H. A., & Amstutz, H. C. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199810)42:1<103::aid-jbm13>3.0.co;2-m · Cited by 431
Metadata
- Authors
- Sunderman, F. W., Hopfer, S. M., Swift, T., Rezuke, W. N., Ziebka, L., Highman, P., Edwards, B., Folcik, M., & Gossling, H. R.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1989-05
- Volume
- 7
- Issue
- 3
- Pages
- 307-315
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2039167904
- Cited by
- 211
- References
- 0
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cobalt, chromium, and nickel concentrations in body fluids of patients with porous‐coated knee or hip prostheses. https://app.cochat.ai/papers/10.1002/jor.1100070302
- The paper
- Sunderman, F. W., Hopfer, S. M., Swift, T., Rezuke, W. N., Ziebka, L., Highman, P., Edwards, B., Folcik, M., & Gossling, H. R. (1989). Cobalt, chromium, and nickel concentrations in body fluids of patients with porous‐coated knee or hip prostheses. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100070302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.