Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 198

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Effects of experimental graded compression on blood flow in spinal nerve roots. A vital microscopic study on the porcine cauda equina

Olmarker, Kjell, Rydevik, Björn, Holm, Sten, Bagge, Ulf·1989·Journal of Orthopaedic Research

Abstract

Compression injuries of spinal nerve roots are very common. However the basic pathophysiology of these conditions is not fully understood. In this study a model is presented for experimental graded compression of the nerve roots of the pig cauda equina, including a technique for vital microscopic studies on the microcirculation flow of the intrinsic vessels of the nerve roots during compression. With this model critical pressure levels for compressioninduced occlusion of the arterioles. capillaries, and venules of the intrinsic vasculature of the nerve roots were determined. The study showed that the average minimum pressure in the inflated balloon required to stop the flow in the arterioles was 127 mm Hg (SD = 18, n = 11), in the capillaries 40 mm Hg (SD = 6, n = 12), and in the venules 30 mm Hg (SD = 10, n = 12). The average mean arterial pressure (MAP) was 150 mm Hg (SD = 14, n = 12). There was a statistically significant correlation (p > 0.001) between the MAP and the pressure required to stop the flow in the arterioles (r = 0.83, n = 14), but no correlation between MAP and capillary (r = 0.09 NS, n = 20) or venular (r = −0.28 NS, n = 34) occlusion pressure. After the nerve roots had been compressed at 50 or 200 mm Hg for 10 min or 2 h, the recirculation started immediately. There was a hyperemia during the first 10 min, with a dilatation of the vessels, particularly the venules. In nerve roots exposed to compression for 2 h at either 50 or 200 mm Hg, an intraneural edema developed. Compression can thus induce changes in the blood flow of spinal nerve roots and may, even at low pressures where only venular congestion occurs, lead to alteration in function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jor.1100070607

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Metadata

Authors
Olmarker, K., Rydevik, B., Holm, S., & Bagge, U.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
1989-11
Volume
7
Issue
6
Pages
817-823
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2022907029
Cited by
198
References
1
FWCI
2.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of experimental graded compression on blood flow in spinal nerve roots. A vital microscopic study on the porcine cauda equina. https://app.cochat.ai/papers/10.1002/jor.1100070607
The paper
Olmarker, K., Rydevik, B., Holm, S., & Bagge, U. (1989). Effects of experimental graded compression on blood flow in spinal nerve roots. A vital microscopic study on the porcine cauda equina. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100070607

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.