Method for the measurement of friction between tendon and pulley
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
An experimental system was developed that allows direct measurement of friction at the tendon‐pulley interface, and the results were interpreted by use of a theoretical model for friction of a cable around a fixed pulley. Validation experiments were conducted with a nylon cable around a nylon rod. One end of the cable was connected to an actuator via a load cell, and the other end was connected to a 4.9 N load via a similar load cell. The cable was passed around the nylon rod and then pulled toward the actuator. Tests were performed at five different arcs of contact. The friction forces, as measured by the difference between two load transducers, were compared with those determined for a theoretical model and were used for calculation of the friction coefficient. The measurement system then was used to study the friction force between the flexor digitorum profundus tendon and the A2 pulley on nine fresh frozen index digits. The method allows us to measure the direct interaction between the tendon and pulley and could be used to evaluate and compare procedures for tendon‐pulley and pulley repair and reconstruction, as well as for the study of tendon‐pulley friction in various pathological conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basic Orthopaedic Biomechanics
&NA; (1991) · Journal of Clinical Engineering · doi:10.1097/00004669-199111000-00020 · Cited by 307
Clinical Mechanics of the Hand
Seyfer, A. E. (1994) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199404000-00043 · Cited by 279
Anatomy of the finger flexor tendon sheath and pulley system
Doyle, J. R. (1988) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(88)80082-0 · Cited by 224
Functional anatomy of the human digital flexor pulley system
Lin, G.-T., Amadio, P. C., An, K.-N., & Cooney, W. P. (1989) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(89)80043-7 · Cited by 186
Self-citationQuantifying exposure in occupational manual tasks with cumulative trauma disorder potential
MOORE, A., WELLS, R., & RANNEY, D. (1991) · Ergonomics · doi:10.1080/00140139108964888 · Cited by 177
Some biomechanical aspects of the carpal tunnel
Armstrong, T. J., & Chaffin, D. B. (1979) · Journal of Biomechanics · doi:10.1016/0021-9290(79)90045-9 · Cited by 172
Analysis of cumulative strain in tendons and tendon sheaths
Goldstein, S. A., Armstrong, T. J., Chaffin, D. B., & Matthews, L. S. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90261-2 · Cited by 126
Cited by
The Scientific Basis for Advances in Flexor Tendon Surgery
Strickland, J. W. (2005) · Journal of Hand Therapy · doi:10.1197/j.jht.2005.01.013 · Cited by 179
Relationships and Mechanisms Between Occupational Risk Factors and Distal Upper Extremity Disorders
Keir, P. J., Farias Zuniga, A., Mulla, D. M., & Somasundram, K. G. (2021) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720819860683 · Cited by 57
Metadata
- Authors
- Uchiyama, S., Coert, J. H., Berglund, L., Amadio, P. C., & An, K. ‐.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1995-01
- Volume
- 13
- Issue
- 1
- Pages
- 83-89
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2117028371
- Cited by
- 159
- References
- 7
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.