In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur
The DOI matches its Crossref record.
Abstract
Two conflicting theories exist concerning the stress pattern for the proximal lateral aspect of the human femur. According to the classic theory of Pauwels, a bending moment on the femur leads to compression medially and to tension laterally. The alternative theory is that muscle forces contribute to a moment‐free loading of the femur, with both the medial and lateral cortices subjected to compression. To examine these theories, we measured the strain at the external surface of the proximal lateral aspect of the femur of two female patients undergoing surgery for “snapping hip syndrome.” During the surgical procedure, a strain‐gauge rosette was bonded to the lateral aspect of the femur and the cortical strains were monitored while the patient performed a series of activities. In both patients, principle tensile strain increased significantly during one‐legged stance, walking, and stair climbing as compared with that during two‐legged stance. During each loading situation, the principal tensile strain was aligned within 22° to the longitudinal femoral axis. Dynamic strain measurements consistently revealed tensile axial strain at the lateral aspect of the femur during each activity. The present studv supports the classic bending theory of Pauwels and demonstrates that the proximal lateral aspect of the femur is subjected to tension during the stance phase of gait.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Who’s afraid of the big bad Wolff?: “Wolff’s law” and bone functional adaptation
Ruff, C., Holt, B., & Trinkaus, E. (2006) · American Journal of Physical Anthropology · doi:10.1002/ajpa.20371 · Cited by 994
Body size, body shape, and long bone strength in modern humans
Ruff, C. B. (2000) · Journal of Human Evolution · doi:10.1006/jhev.1999.0322 · Cited by 382
Long bone articular and diaphyseal structure in old world monkeys and apes. I: Locomotor effects
Ruff, C. B. (2002) · American Journal of Physical Anthropology · doi:10.1002/ajpa.10117 · Cited by 362
Biomechanical considerations of animal models used in tissue engineering of bone
Liebschner, M. A. K. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00515-5 · Cited by 329
Taylor, M., & Prendergast, P. J. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.019 · Cited by 199
“What do we know? The joint contact forces have been measured in a small number of hip replacement patients [98-100] and there has been a single study where the strains have been measured on the lateral aspect of the femur of two patients for a limited range of activities[101].”
Background
Metadata
- Authors
- Aamodt, A., Lund‐Larsen, J., Eine, J., Andersen, E., Benum, P., & Husby, O. S.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1997-11
- Volume
- 15
- Issue
- 6
- Pages
- 927-931
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2053171342
- Cited by
- 121
- References
- 0
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur. https://app.cochat.ai/papers/10.1002/jor.1100150620
- The paper
- Aamodt, A., Lund‐Larsen, J., Eine, J., Andersen, E., Benum, P., & Husby, O. S. (1997). In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100150620
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.