Introduction of a new interlocked intramedullary nailing device for stabilization of critically sized femoral defects in the rat: A combined biomechanical and animal experimental study
The DOI matches its Crossref record.
Abstract
The goals of this study were to develop a new intramedullary, rotation‐stable locking device and evaluate it biomechanically and in vivo for maintenance of a critical size osteotomy gap in a model of conscious pseudarthrosis. In standardized osteotomized rat femora (5 mm osteotomy gap) two different rotation‐ and axial‐stable locking devices (group pS + cS) were tested in vitro with respect to biomechanics and compared to a control group without an additional locking device (K; n = 6 for each group). For in vivo studies, 27 male Sprague Dawley rats (250–300 g) underwent a femoral defect osteotomy of critical size and were stabilized by one of the three methods (n = 9 for each group). All groups were examined radiologically postoperatively, after 14 days, and after 12 weeks. In vitro testing revealed higher compression and torsional rigidities for the two locking devices (p < 0.05) compared to the control group (compression rigidity: pS = 103.6 ± 13.2; cS = 91.3 ± 10.9; K = 52.8 ± 8.4 N/mm; torsional rigidity: pS = 5.9 ± 0.9; cS = 4.3 ± 1.4; K = 0.4 ± 0.1 Nmm/°). In vivo, group K and pS exhibited up to two thirds wire dislocation and reduction of the osteotomy gap, while dislocation was less frequent in the cS group. Thus, the locking device with compression of the wire showed advantages in rotational and axial stability for a critically sized defect, though the osteotomy gap could not be maintained in all cases over the 12‐week period. Nevertheless, our data corroborate the necessity of an internal fixation device with sufficient axial and rotational stability. © 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 26:184–189, 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sildenafil accelerates fracture healing in mice
Histing, T., Marciniak, K., Scheuer, C., Garcia, P., Holstein, J. H., Klein, M., Matthys, R., Pohlemann, T., & Menger, M. D. (2011) · Journal of Orthopaedic Research® · doi:10.1002/jor.21324 · Cited by 56
Stimulation of angiogenesis by cilostazol accelerates fracture healing in mice
Herath, S. C., Lion, T., Klein, M., Stenger, D., Scheuer, C., Holstein, J. H., Mörsdorf, P., Rollmann, M. F. R., Pohlemann, T., Menger, M. D., et al. (2015) · Journal of Orthopaedic Research® · doi:10.1002/jor.22967 · Cited by 20
Amlodipine accelerates bone healing in a stable closed femoral fracture model in mice
Department of Trauma and Reconstructive Surgery, E. K. U. T., Menger, M., Merscher, B., Scheuer, C., Braun, B., Herath, S., Rollmann, M., Stenger, D., Später, T., Pohlemann, T., et al. (2021) · European Cells and Materials · doi:10.22203/ecm.v041a38 · Cited by 16
“In fact, various clinical and experimental studies suggest that CCBs influence skeletal calcium metabolism due to the presence of L-type channels in osteoblastic cells (Shimizu et al., 2012).”
Background
Metadata
- Authors
- Schoen, M., Rotter, R., Schattner, S., Mittlmeier, T., Claes, L., Vollmar, B., & Gradl, G.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2007-09-14
- Volume
- 26
- Issue
- 2
- Pages
- 184-189
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2084054732
- Cited by
- 37
- References
- 0
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Introduction of a new interlocked intramedullary nailing device for stabilization of critically sized femoral defects in the rat: A combined biomechanical and animal experimental study. https://app.cochat.ai/papers/10.1002/jor.20501
- The paper
- Schoen, M., Rotter, R., Schattner, S., Mittlmeier, T., Claes, L., Vollmar, B., & Gradl, G. (2008). Introduction of a new interlocked intramedullary nailing device for stabilization of critically sized femoral defects in the rat: A combined biomechanical and animal experimental study. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.20501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.