The DOI matches its Crossref record.
The proximal hip joint capsule and the zona orbicularis contribute to hip joint stability in distraction
Open accessAbstract
The structure and function of the proximal hip joint capsule and the zona orbicularis are poorly understood. We hypothesized that the zona orbicularis is an important contributor to hip stability in distraction. In seven cadaveric hip specimens from seven male donors we distracted the femur from the acetabulum in a direction parallel to the femoral shaft with the hip in the neutral position. Eight sequential conditions were assessed: (1) intact specimen (muscle and skin removed), (2) capsule vented, (3) incised iliofemoral ligament, (4) circumferentially incised capsule, (5) partially resected capsule (distal to the zona orbicularis), (6) completely resected capsule, (7) radially incised labrum, and (8) completely resected labrum. The reduction of the distraction load was greatest between the partially resected capsule phase and completely resected capsule phase at 1, 3, and 5 mm joint distraction (p = 0.018). The proximal to middle part of the capsule, which includes the zona orbicularis, appears grossly and biomechanically to act as a locking ring wrapping around the neck of the femur and is a key structure for hip stability in distraction. © 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27: 989–995, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mohtadi, N. G. H., Griffin, D. R., Pedersen, M. E., Chan, D., Safran, M. R., Parsons, N., Sekiya, J. K., Kelly, B. T., Werle, J. R., Leunig, M., et al. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2012.03.013 · Cited by 483
Self-citationDomb, B. G., Philippon, M. J., & Giordano, B. D. (2013) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2012.04.057 · Cited by 331
Nepple, J. J., Philippon, M. J., Campbell, K. J., Dornan, G. J., Jansson, K. S., LaPrade, R. F., & Wijdicks, C. A. (2014) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-014-2875-y · Cited by 324
Microinstability of the hip--it does exist: etiology, diagnosis and treatment
Kalisvaart, M. M., & Safran, M. R. (2015) · Journal of Hip Preservation Surgery · doi:10.1093/jhps/hnv017 · Cited by 210
Self-citationEffect of Acetabular Labrum Tears on Hip Stability and Labral Strain in a Joint Compression Model
Smith, M. V., Panchal, H. B., Ruberte Thiele, R. A., & Sekiya, J. K. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546511400981 · Cited by 117
Akiyama, K., Sakai, T., Koyanagi, J., Yoshikawa, H., & Sugamoto, K. (2011) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2011.01.017 · Cited by 48
Evaluation of atraumatic hip instability measured by triaxial accelerometry during walking
Neira, A., Amenabar, T., Cristi-Sánchez, I., Rafols, C., Monckeberg, J. E., Belemmi, M., Neira, M., Soldan, M., & Silvestre, R. (2019) · Journal of Hip Preservation Surgery · doi:10.1093/jhps/hnz018 · Cited by 4
Metadata
- Authors
- Ito, H., Song, Y., Lindsey, D. P., Safran, M. R., & Giori, N. J.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2009-01-15
- Volume
- 27
- Issue
- 8
- Pages
- 989-995
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2003703944
- Cited by
- 179
- References
- 0
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.