Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 26

The DOI matches its Crossref record.

A New Method to Evaluate the Antimicrobial Efficacy of Domestic Laundry Detergents

Schages, Jan, Stamminger, Rainer, Bockmühl, Dirk P. · 2020 · Journal of Surfactants and Detergents

Abstract

During the last decades, the strive for energy efficiency lead to lower washing temperatures in laundering processes. In this regard, there is a rising need to measure the antimicrobial action of laundry detergents and additives, since chemistry must be considered an important means to compensate for the loss of temperature. Although there is an existing standard method (EN 16616) to evaluate the antimicrobial efficacy of detergents for the medical area, this method does not reflect the domestic situation and neglects important steps, such as the rinse cycles. Hence, we developed an experimental setup, which represents the whole washing process and reflects the domestic situation by using a household‐related setting. The suggested method uses a lab‐scale washing machine, which does not only allow to test products that can be applied throughout the whole laundering process (including the rinse steps) but also proved to be able to show the impact of different parameters (e.g., detergent ingredient or different types of textiles) in a very systematic manner.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jsde.12401

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 35

  1. 10.1111/ijcs.12149 · DOI
  2. 10.1111/ijd.12167 · DOI · Paper page
  3. Arild A.‐H., 2003, An investigation of domestic laundry in Europe ‐ habits, hygiene and technical performance
  4. Bast E., 2010, Mikrobiologische Methoden‐Eine Einführung in grundlegende Arbeitstechniken
  5. Bellante S., 2011, Hygienische Aufbereitung von Textilien in Privathaushalten‐eine Studie aus der Praxis, Hygiene & Medizin, 36, 300
  6. Block C., 2001, Determination of the microbicidal effect of laundry detergents, Tenside Surfactants Detergents, 38, 140, 10.1515/tsd-2001-380303 · doi:10.1515/tsd-2001-380303
  7. 10.1046/j.1365-2672.1997.00199.x · DOI
  8. Bloomfield S. F., 2011, The infection risks associated with clothing and household linens in home and everyday life settings, and the role of laundry, International Scientific Forum on Home Hygiene, 1
  9. Bockmühl D. P., 2011, Hygiene aspects in domestic laundry, Hygiene & Medizin, 36, 280
  10. 10.1111/jam.13402 · DOI
  11. 10.1016/S0195-6701(96)90065-1 · DOI
  12. 10.3139/113.110584 · DOI
  13. Deutsches Institut für Normung, 2003, DIN 53919 Teil 1: Standardbaumwollgewebe zur Beurteilung von Waschverfahren
  14. Deutsches Institut für Normung, 2012, DIN EN 60456:2012–03 Clothes washing machines for household use—Methods for measuring the performance (IEC 60456:2010, modified)
  15. Deutsches Institut für Normung, 2015, DIN EN 16616:2015–10 Chemical disinfectants and antiseptics—Chemical‐thermal textile disinfection—Test method and requirements
  16. Fijan S. Koren S. Cencic A. &Sostar‐Turk S.(2007)Antimicrobial disinfection effect of a laundering proceedure for hospital textiles against various indicator bacteria and fungi using different substrates for simulating human excrements. · doi:10.1016/j.diagmicrobio.2006.08.020
  17. 10.1007/s11046-010-9347-9 · doi:10.1007/s11046-010-9347-9
  18. Honisch M., 2017, Antimicrobial efficacy of laundering processes
  19. 10.1111/jam.12647 · DOI · Paper page
  20. 10.3139/113.110465 · DOI
  21. Industrievereinigung Chemiefaser e.V, 2014, Die Chemiefaserindustrie in der Bundesrepublik Deutschland
  22. 10.1111/j.1745-4506.2005.00002.x · DOI
  23. 10.1023/A:1016378226861 · DOI
  24. 10.1111/ijcs.12091 · DOI
  25. 10.1128/AEM.07816-11 · DOI
  26. 10.1111/j.1470-6431.2011.01081.x · DOI
  27. Lichtenberg W., 2006, Hygieneaspekte beim Niedrigtemperaturwaschen, SÖFW‐Journal, 2006, 28
  28. Linke S., 2011, Orientating investigation of the inactivation of Staphylococcus aureus in the laundry process, Hygiene & Medizin, 36, 8
  29. Lucassen R., 2014, The washing machine as a source of microbial contamination of domestic laundry—a case study, Household Personal Care Today, 9, 54
  30. 10.1007/s001050050600 · doi:10.1007/s001050050600
  31. Sinner H., 1959, Über das Waschen mit Haushaltswaschmaschinen
  32. 10.1111/lam.12050 · doi:10.1111/lam.12050
  33. 10.1002/ffj.2088 · DOI
  34. 10.1111/j.1365-2672.2009.04434.x · DOI
  35. Verbund für Angewandte Hygiene e.V. (VAH), 2016, Anforderungen und Methoden zur VAH‐Zertifizierung chemischer Desinfektionsverfahren

Cited by

Metadata

Authors
Schages, J., Stamminger, R., & Bockmühl, D. P.
Affiliations
  • Faculty of Life Sciences, Hygiene and Microbiology Rhine‐Waal University of Applied Sciences Kleve Germany
  • Institute of Agricultural Engineering, Section of Household and Appliance Technology University of Bonn Bonn Germany
Venue
Journal of Surfactants and Detergents
Publisher
Wiley
Published
2020-02-21
Volume
23
Issue
3
Pages
629-639
ISSN
  • 1097-3958
  • 1558-9293
Cited by
26
References
0
Language
en
Funders
  • Procter and Gamble
  • Unilever

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.