Liquid‐phase microextraction combined with liquid chromatography‐mass spectrometry. Extraction from small volumes of biological samples
The DOI matches its Crossref record.
Abstract
Liquid‐phase microextraction (LPME) is a sample preparation technique based on disposable polypropylene hollow fibres, which results in efficient sample clean‐up and high preconcentration. The present paper describes the combination of LPME with LC‐MS utilising electrospray ionisation for high sensitivity. Nine antidepressant drugs were extracted from 50 or 500 μL of plasma or whole blood samples, through a thin layer of dodecyl acetate immobilised in the pores of the hollow fibre, and into 15 μL of 200 mM formic acid as acceptor solution inside the hollow fibre. Analyte recoveries in the range 12–68% and 9–52% were obtained from 50 μL of plasma and whole blood respectively. The acceptor solution (15 μL) was diluted with 60 μL of 5 mM ammonium formate pH = 2.7 prior to injection into the LC‐MS system. The system was qualitatively investigated for matrix effects utilising a post‐column infusion system. Whole blood from 5 different persons was cleaned‐up by LPME and injected onto the analytical column while a solution of the 9 model compounds was continuously infused post‐column. No signs of ion suppression were seen for any of the model compounds. Limits of quantification (S/N = 10) were in the low ng/mL range for 6 of the 9 model compounds utilising a whole blood sample volume of only 50 μL. The repeatability of the extractions was investigated utilising paroxetine as internal standard. Acceptable RSDs (%) were obtained (< 20%) for 5 of the antidepressants. By increasing the sample volume from 50 to 500 μL of whole blood RSDs below 20% (3–16%) were observed for all 8 antidepressants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pedersen-Bjergaard, S., & Rasmussen, K. E. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.088 · Cited by 486
Self-citationLee, J., Lee, H. K., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.050 · Cited by 398
Self-citation25,000-fold pre-concentration in a single step with liquid-phase microextraction
Ho, T. S., Vasskog, T., Anderssen, T., Jensen, E., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.04.014 · Cited by 70
Self-citationLiquid-Phase Microextraction in Bioanalytical Sample Preparation
Lucena, R., Cruz-Vera, M., Cárdenas, S., & Valcárcel, M. (2009) · Bioanalysis · doi:10.4155/bio.09.16 · Cited by 55
Metadata
- Authors
- Halvorsen, T. G., Pedersen‐Bjergaard, S., Reubsaet, J. L. E., & Rasmussen, K. E.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2003-11
- Volume
- 26
- Issue
- 17
- Pages
- 1520-1526
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2088473543
- Cited by
- 46
- References
- 0
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.