Determination of phthalic monoesters in aqueous and urine samples by solid‐phase microextraction–diazomethane on‐fibre derivatization–gas chromatography–mass spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A solvent‐free analytical methodology for the determination of phthalic monoesters (MPs) with diazomethane on‐fibre derivatization using solid‐phase microextraction–gas chromatography–mass spectrometry (SPME–DOFD–GC–MS) was developed. Among the different SPME fibres evaluated, the polydimethylsiloxane/divinylbenzene (PDMS/DVB) proved to be the most suitable for the determination of four MPs. The diazomethane on‐fibre derivatization (DOFD) procedure was improved, avoiding diethyl ether as solvent. Equilibrium conditions were reached (15 min) and K′MP values were calculated. Under optimum MP extraction conditions (e. g. direct immersion, 4 mL of sample, 25°C extraction temperature, stirring at 1 100 rpm, 20 min extraction time, 10 min derivatization reaction, and pH = 1.5), trace level concentrations of MPs (0.3–8.6 ng/mL) were detected, allowing the simultaneous determination of phthalic diesters (DPs). The overall SPME–GC–MS precision was improved by using four deuterated internal standards. The developed analytical methodology was applied to different environmental water matrices and human urine samples at MP concentrations ranging from 0.1–538 ng/mL. The developed analytical procedure is robust (50 analyses with the same fibre), rapid (40 min), and of low cost, improving the conventional analysis methods in terms of analysis time, background levels, and cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levels of Seven Urinary Phthalate Metabolites in a Human Reference Population
Blount, B. C., Silva, M. J., Caudill, S. P., Needham, L. L., Pirkle, J. L., Sampson, E. J., Lucier, G. W., Jackson, R. J., & Brock, J. W. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.00108979 · Cited by 634
Cited by
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D., & Ternes, T. A. (2014) · Analytical Chemistry · doi:10.1021/ac500508t · Cited by 2,144
Hauser, R., & Calafat, A. M. (2005) · Occupational and Environmental Medicine · doi:10.1136/oem.2004.017590 · Cited by 941
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D., & Ternes, T. A. (2005) · Analytical Chemistry · doi:10.1021/ac058022x · Cited by 363
Net, S., Delmont, A., Sempéré, R., Paluselli, A., & Ouddane, B. (2015) · Science of The Total Environment · doi:10.1016/j.scitotenv.2015.02.013 · Cited by 284
Uptake and Metabolism of Phthalate Esters by Edible Plants
Sun, J., Wu, X., & Gan, J. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b01233 · Cited by 278
Metadata
- Authors
- Alzaga, R., Peña, A., & Bayona, J. M.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2003-01
- Volume
- 26
- Issue
- 1-2
- Pages
- 87-96
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2170093022
- Cited by
- 44
- References
- 1
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.