Improved high‐performance liquid chromatographic determination of guanidino compounds by pre‐column dervatization with ninhydrin and fluorescence detection
The DOI matches its Crossref record.
Abstract
Ninhydrin has been investigated as a pre‐column derivatization reagent for guanidino compounds. The reaction takes place under strongly alkaline conditions, followed by a second step at low pH and elevated temperature. This procedure yields derivatives with favourable fluorescence properties (excitation at 390 nm, emission at 470 nm). Amino acids do not react with ninhydrin under these conditions so that the method can easily be used for biological samples. Reversed‐phase HPLC separations of the derivatives of several representative guanidino compounds in human blood have been achieved with gradients consisting of aqueous formic acid and methanol. Fluorescence detection yields quantification limits of about 20 μg L–1. Hyphenation with electrospray mass spectrometry has been used to confirm the identity of the derivatives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deminice, R., Rosa, F. T., Franco, G. S., da Cunha, S. F. C., de Freitas, E. C., & Jordao, A. A. (2014) · European Journal of Nutrition · doi:10.1007/s00394-013-0636-1 · Cited by 20
Domingues, W. J. R., Ritti-Dias, R. M., Cucato, G. G., Wolosker, N., Zerati, A. E., Puech-Leão, P., Nunhes, P. M., Moliterno, A. A., & Avelar, A. (2020) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2019.07.008 · Cited by 12
Robinson, J. L., McBreairty, L. E., Ryan, R. A., Randunu, R., Walsh, C. J., Martin, G. M., Brunton, J. A., & Bertolo, R. F. (2020) · PLOS ONE · doi:10.1371/journal.pone.0226806 · Cited by 9
da Silva, R. P. (2022) · Nutrients · doi:10.3390/nu14030701 · Cited by 4
Metadata
- Authors
- Buchberger, W., & Ferdig, M.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2004-11
- Volume
- 27
- Issue
- 15-16
- Pages
- 1309-1312
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2043030073
- Cited by
- 47
- References
- 0
- FWCI
- 0.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved high‐performance liquid chromatographic determination of guanidino compounds by pre‐column dervatization with ninhydrin and fluorescence detection. https://app.cochat.ai/papers/10.1002/jssc.200401866
- The paper
- Buchberger, W., & Ferdig, M. (2004). Improved high‐performance liquid chromatographic determination of guanidino compounds by pre‐column dervatization with ninhydrin and fluorescence detection. Journal of Separation Science. https://doi.org/10.1002/jssc.200401866
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.