CoChat

Liquid‐phase microextraction of basic drugs – Selection of extraction mode based on computer calculated solubility data

Pedersen‐Bjergaard, Stig, Rasmussen, Knut Einar, Brekke, Anders, Ho, Tung Si, Grønhaug Halvorsen, Trine · 2005 · Journal of Separation Science
Cited by 51

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The extractability of 58 different basic drugs by 3‐phase liquid‐phase microextraction (LPME) was studied. Extraction recoveries were correlated to solubility data and log D data calculated with a commercial computer program. The basic drugs were extracted from 1.5 mL water samples (pH 13) through approximately 15 μL of dodecyl acetate immobilized within the pores of a porous polypropylene hollow fibre (organic phase), and into 15 μL of 10 mM HCl (acceptor solution) present inside the lumen of the hollow fibre. Compounds with a calculated solubility below 1 mg/mL at pH 2 were poorly recovered and remained principally in the organic phase. For these drugs, 2‐phase LPME may be used as an alternative technique, where the aqueous acceptor phase is replaced by an organic solvent. In the solubility range 1–5 mg/mL, most drugs were effectively extracted (recovery > 30%), whereas drugs belonging to the solubility range 5–150 mg/mL were all extracted with recoveries above 30% by 3‐phase LPME. The hydrophilic nature of most drugs with solubilities above 150 mg/mL prevented them from entering the organic phase, and only those with log D >1.8 were effectively recovered by 3‐phase LPME. For drugs with log D < 1.8 (and solubility > 150 mg/mL), carrier‐mediated LPME was found to be the preferred technique, where an ion‐pair reagent (octanoic acid) was added to the sample. In the case of carrier‐mediated LPME, the volume of sample was decreased to 100 μL to facilitate rapid extractions. Based on the present work, the extractability of new compounds may easily be predicted to speed up method development. Extractions were also accomplished from plasma samples, where interactions between proteins and the drugs may reduce the extraction recovery. However, dilution of the plasma samples with water and adjustment of pH into the alkaline region effectively suppressed drug‐protein interactions for most of the drugs studied.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jssc.200401935

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Pedersen‐Bjergaard, S., Rasmussen, K. E., Brekke, A., Ho, T. S., & Grønhaug Halvorsen, T.
Venue
Journal of Separation Science
Publisher
Wiley
Published
2005-07
Volume
28
Issue
11
Pages
1195-1203
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W2168290837
Cited by
51
References
1
FWCI
4.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.