Ionic liquid‐based single‐drop liquid‐phase microextraction combined with high‐performance liquid chromatography for the determination of sulfonamides in environmental water
The DOI matches its Crossref record.
Abstract
A simple, rapid and environment‐friendly technique of single‐drop liquid‐phase microextraction has been developed for the determination of sulfonamides in environmental water. Several important parameters including stirring rate, extraction solvent, extraction pH, salinity and extraction time were optimized to maximize the extract efficiency. Extraction solvent 1‐octyl‐3‐methylimidazolium hexafluorophosphate [C 8 MIM][PF 6] ionic liquid showed better extraction efficiency than 1‐butyl‐3‐methylimidazolium hexafluorophosphate [C 4 MIM][PF 6] and 1‐octanol. The optimum experimental conditions were: pH, 4.5; sodium chloride content, 36% w/v; extraction time, 20 min. This method provided low detection limits (0.5–1 ng/mL), good repeatability (the RSD ranging from 4.2 to 9.9%, n=5) and wide linear range (1–1500 ng/mL), with determination coefficients (r2) higher than 0.9989 for all the target compounds. Real sample analysis showed relative recoveries between 63.5 and 115.8% for all the target compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kanu, A. B. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462444 · Cited by 271
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Application of ionic liquid in liquid phase microextraction technology
Han, D., Tang, B., Ri Lee, Y., & Ho Row, K. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200486 · Cited by 103
Opportunities and shortcomings of ionic liquids in single-drop microextraction
Marcinkowski, Ł., Pena-Pereira, F., Kloskowski, A., & Namieśnik, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.03.024 · Cited by 69
Application of ionic liquids for liquid–liquid microextraction
Zhang, P., Hu, L., Lu, R., Zhou, W., & Gao, H. (2013) · Analytical Methods · doi:10.1039/c3ay40597d · Cited by 50
Metadata
- Authors
- Guo, X., Yin, D., Peng, J., & Hu, X.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2012-01-19
- Volume
- 35
- Issue
- 3
- Pages
- 452-458
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2022278104
- Cited by
- 63
- References
- 0
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ionic liquid‐based single‐drop liquid‐phase microextraction combined with high‐performance liquid chromatography for the determination of sulfonamides in environmental water. https://app.cochat.ai/papers/10.1002/jssc.201100777
- The paper
- Guo, X., Yin, D., Peng, J., & Hu, X. (2012). Ionic liquid‐based single‐drop liquid‐phase microextraction combined with high‐performance liquid chromatography for the determination of sulfonamides in environmental water. Journal of Separation Science. https://doi.org/10.1002/jssc.201100777
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.