Separation optimization of long porous‐layer open‐tubular columns for nano‐LC–MS of limited proteomic samples
The DOI matches its Crossref record.
Abstract
The single‐run resolving power of current 10 μm id porous‐layer open‐tubular (PLOT) columns has been optimized. The columns studied had a poly(styrene‐co‐divinylbenzene) porous layer (∼0.75 μm thickness). In contrast to many previous studies that have employed complex plumbing or compromising set‐ups, SPE–PLOT‐LC‐MS was assembled without the use of additional hardware/noncommercial parts, additional valves or sample splitting. A comprehensive study of various flow rates, gradient times, and column length combinations was undertaken. Maximum resolution for <400 bar was achieved using a 40 nL/min flow rate, a 400 min gradient and an 8 m long column. We obtained a 2.3‐fold increase in peak capacity compared to previous PLOT studies (950 versus previously obtained 400, when using peak width = 2σ definition). Our system also meets or surpasses peak capacities obtained in recent reports using nano‐ultra‐performance LC conditions or long silica monolith nanocolumns. Nearly 500 proteins (1958 peptides) could be identified in just one single injection of an extract corresponding to 1000 B x PC 3 beta catenin (−/−) cells, and ∼1200 and 2500 proteins in extracts of 10 000 and 100 000 cells, respectively, allowing detection of central members and regulators of the W nt signaling pathway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Simone, P., Pierri, G., Foglia, P., Gasparrini, F., Mazzoccanti, G., Capriotti, A. L., Ursini, O., Ciogli, A., & Laganà, A. (2016) · Journal of Separation Science · doi:10.1002/jssc.201500844 · Cited by 24
Ali, F., & Cheong, W. J. (2015) · Journal of Separation Science · doi:10.1002/jssc.201500765 · Cited by 18
Ali, F., & Cheong, W. J. (2016) · Bulletin of the Korean Chemical Society · doi:10.1002/bkcs.10859 · Cited by 9
Metadata
- Authors
- Rogeberg, M., Vehus, T., Grutle, L., Greibrokk, T., Wilson, S. R., & Lundanes, E.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2013-09
- Volume
- 36
- Issue
- 17
- Pages
- 2838-2847
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2125744110
- Cited by
- 44
- References
- 0
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Separation optimization of long porous‐layer open‐tubular columns for nano‐LC–MS of limited proteomic samples. https://app.cochat.ai/papers/10.1002/jssc.201300499
- The paper
- Rogeberg, M., Vehus, T., Grutle, L., Greibrokk, T., Wilson, S. R., & Lundanes, E. (2013). Separation optimization of long porous‐layer open‐tubular columns for nano‐LC–MS of limited proteomic samples. Journal of Separation Science. https://doi.org/10.1002/jssc.201300499
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.