Ionic‐liquid‐based dispersive liquid–liquid microextraction combined with magnetic solid‐phase extraction for the determination of aflatoxins B1, B2, G1, and G2 in animal feeds by high‐performance liquid chromatography with fluorescence detection
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A novel two‐step extraction technique combining ionic‐liquid‐based dispersive liquid–liquid microextraction with magnetic solid‐phase extraction was developed for the preconcentration and separation of aflatoxins in animal feedstuffs before high‐performance liquid chromatography coupled with fluorescence detection. In this work, ionic liquid 1‐octyl‐3‐methylimidazolium hexafluorophosphate was used as the extractant in dispersive liquid–liquid microextraction, and hydrophobic pelargonic acid modified Fe 3 O 4 magnetic nanoparticles as an efficient adsorbent were applied to retrieve the aflatoxins‐containing ionic liquid. Notably, the target of magnetic nanoparticles was the ionic liquid rather than the aflatoxins. Because of the rapid mass transfer associated with the dispersive liquid–liquid microextraction and magnetic solid phase steps, fast extraction could be achieved. The main parameters affecting the extraction recoveries of aflatoxins were investigated and optimized. Under the optimum conditions, vortexing at 2500 rpm for 1 min in the dispersive liquid–liquid microextraction and magnetic solid‐phase extraction and then desorption by sonication for 2 min with acetonitrile as eluent. The recoveries were 90.3–103.7% with relative standard deviations of 3.2–6.4%. Good linearity was observed with correlation coefficients ranged from 0.9986 to 0.9995. The detection limits were 0.632, 0.087, 0.422 and 0.146 ng/mL for aflatoxins B 1, B2, G1, and G2, respectively. The results were also compared with the pretreatment method carried out by conventional immunoaffinity columns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Temperature-controlled ionic liquid dispersive liquid phase micro-extraction
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.103 · Cited by 303
Cited by
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Ge, D., Zhang, Y., Dai, Y., & Yang, S. (2018) · Journal of Separation Science · doi:10.1002/jssc.201701282 · Cited by 121
Sajid, M., & Alhooshani, K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.016 · Cited by 98
Du, W., Yao, L., Bian, J., Liu, Y., Wang, X., Zhang, J., & Pang, L. (2018) · Analytical Methods · doi:10.1039/c8ay00800k · Cited by 18
Karibayev, M., Tugelbay, S., Amankeldiyeva, A., Akilbekov, B., Ibrayem, T., Zhengis, A., Shah, D., Nurgalieva, D., & Baisalova, G. (2026) · Talanta · doi:10.1016/j.talanta.2026.129800 · Cited by 9
Metadata
- Authors
- Zhao, J., Zhu, Y., Jiao, Y., Ning, J., & Yang, Y.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2016-09-07
- Volume
- 39
- Issue
- 19
- Pages
- 3789-3797
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2512655185
- Cited by
- 45
- References
- 1
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ionic‐liquid‐based dispersive liquid–liquid microextraction combined with magnetic solid‐phase extraction for the determination of aflatoxins B1, B2, G1, and G2 in animal feeds by high‐performance liquid chromatography with fluorescence detection. https://app.cochat.ai/papers/10.1002/jssc.201600671
- The paper
- Zhao, J., Zhu, Y., Jiao, Y., Ning, J., & Yang, Y. (2016). Ionic‐liquid‐based dispersive liquid–liquid microextraction combined with magnetic solid‐phase extraction for the determination of aflatoxins B1, B2, G1, and G2 in animal feeds by high‐performance liquid chromatography with fluorescence detection. Journal of Separation Science. https://doi.org/10.1002/jssc.201600671
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.