Magnetic ionic liquid assisted single‐drop microextraction of ascorbic acid before its voltammetric determination
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
For the first time, we coupled a microextraction technique using a magnetic ionic liquid with voltammetric determination. A hydrophobic magnetic ionic liquid that contains the tetrachloromanganate(II) anion, namely, aliquat tetrachloromanganate(II), was synthesized and used for the extraction of ascorbic acid from aqueous solutions followed by voltammetric determination. The extraction procedure was carried out using a single drop microextraction technique in which the ascorbic acid containing magnetic ionic liquid was separated with a magnet and then cast onto the surface of a carbon paste electrode modified with TiO 2 nanoparticles for the voltammetric quantification of the extracted ascorbic acid. Electrochemical quantification was carried out in a blank phosphate buffer solution. After optimizing different experimental conditions, a linear concentration range of 1.50–40.0 nM with a detection limit of 0.43 nM was obtained for the determination of ascorbic acid. The presented approach was successfully applied to the determination of ascorbic acid in samples of vitamin C effervescent tablets and orange juice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic ionic liquids in analytical chemistry: A review
Clark, K. D., Nacham, O., Purslow, J. A., Pierson, S. A., & Anderson, J. L. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.06.011 · Cited by 222
Application of ionic liquid in liquid phase microextraction technology
Han, D., Tang, B., Ri Lee, Y., & Ho Row, K. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200486 · Cited by 103
Cited by
Tang, S., Qi, T., Ansah, P. D., Nalouzebi Fouemina, J. C., Shen, W., Basheer, C., & Lee, H. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.09.016 · Cited by 195
Ionic liquids in the microextraction techniques: The influence of ILs structure and properties
Yavir, K., Konieczna, K., Marcinkowski, Ł., & Kloskowski, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115994 · Cited by 134
Application of ionic liquids in microextraction techniques: Current trends and future perspectives
Marcinkowska, R., Konieczna, K., Marcinkowski, Ł., Namieśnik, J., & Kloskowski, A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.07.025 · Cited by 119
Metadata
- Authors
- Jahromi, Z., Mostafavi, A., Shamspur, T., & Mohamadim, M.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2017-09-13
- Volume
- 40
- Issue
- 20
- Pages
- 4041-4049
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2750466597
- Cited by
- 38
- References
- 2
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.