CoChat

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Enhanced headspace single drop microextraction method using deep eutectic solvent based magnetic bucky gels: Application to the determination of volatile aromatic hydrocarbons in water and urine samples

Yousefi, Seyedeh Mahboobeh, Shemirani, Farzaneh, Ghorbanian, Sohrab Ali · 2018 · Journal of Separation Science

Abstract

A facile headspace single drop microextraction method was developed using deep eutectic solvent‐based magnetic bucky gel as the extraction solvent for the first time. The hydrophobic magnetic bucky gel was formed by combining choline chloride/chlorophenol deep eutectic solvent and magnetic multiwalled carbon nanotube nanocomposite. Magnetic susceptibility, high viscosity, high sorbing ability, and tunable extractability of organic analytes are the desirable advantages of the prepared gel. Using a rod magnet as a suspensor in combination with the magnetic susceptibility of the prepared gel resulted in a highly stable droplet. This stable droplet eliminated the possibility of drop dislodgement. The prepared droplet made it possible to complete the extraction process in high temperatures and elevated agitation rates. Furthermore, using larger micro‐droplet volumes without any operational problems became possible. These facts resulted in shorter sample preparation time, higher sensitivity of the method, and lower detection limits. Under the optimized conditions, an enrichment factor of 520–587, limit of detection of 0.05–0.90 ng/mL, and linearity range of 0.2–2000 ng/mL (coefficient of determination = 0.9982–0.9995) were obtained. Relative standard deviations were < 10%. This method was successfully coupled with gas chromatography and used for the determination of benzene, toluene, ethylbenzene, and xylene isomers as harmful volatile organic compounds in water and urine samples.

Overview

Integrity signals

Registry

Crossref · 10.1002/jssc.201700807

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

2 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 34 references

Cited by

See all 80

Metadata

Authors
Yousefi, S. M., Shemirani, F., & Ghorbanian, S. A.
Affiliations
University of Tehran (IR)
Corresponding author
Shemirani, Farzaneh
Venue
Journal of Separation Science
Publisher
Wiley
Published
2017-12-27
Volume
41
Issue
4
Pages
966-974
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W2772910519
Cited by
79
References
34
Citations by year
2026: 4 · 2025: 3 · 2024: 9 · 2023: 13 · 2022: 11 · 2021: 12 · 2020: 13 · 2019: 8 · 2018: 6
FWCI
5.16
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Separation Science (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
Keywords
headspace single-drop microextraction, deep eutectic solvents, choline chloride, chlorophenols, volatile aromatic hydrocarbons, BTEX, benzene, toluene, ethylbenzene, xylene, water samples, urine samples, sample preparation
MeSH terms
Gels, Humans, Hydrocarbons, Aromatic, Particle Size, Solvents, Water Pollutants, Chemical, Volatile Organic Compounds, Liquid Phase Microextraction, Magnetic Fields, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enhanced headspace single drop microextraction method using deep eutectic solvent based magnetic bucky gels: Application to the determination of volatile aromatic hydrocarbons in water and urine samples. https://app.cochat.ai/papers/10.1002/jssc.201700807
The paper
Yousefi, S. M., Shemirani, F., & Ghorbanian, S. A. (2018). Enhanced headspace single drop microextraction method using deep eutectic solvent based magnetic bucky gels: Application to the determination of volatile aromatic hydrocarbons in water and urine samples. Journal of Separation Science. https://doi.org/10.1002/jssc.201700807

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.