CoChat

Deep eutectic solvent based homogeneous liquid-liquid extraction coupled with in-syringe dispersive liquid-liquid microextraction performed in narrow tube; application in extraction and preconcentration of some herbicides from tea

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

A homogeneous liquid‐liquid extraction performed in narrow tube coupled to in–syringe‐dispersive liquid‐liquid microextraction based on deep eutectic solvent has been developed for the extraction of six herbicides from tea samples. In this method, sodium chloride as a separation agent is filled into the narrow tube and the tea sample is placed on top of the salt. Then a mixture of deionized water and deep eutectic solvent (water miscible) is passed through the tube. In this procedure, the deep eutectic solvent is realized as tiny droplets in contact with salt. By passing the droplets from the tea layer placed on the salt layer, the analytes are extracted into them. After collecting the solvent as separated layer, it is mixed with another deep eutectic solvent (choline chloride/butyric acid) and the mixture is dispersed into deionized water placed in a syringe. After adding acetonitrile to break up the cloudy state, the collected organic phase is injected into gas chromatography‐mass spectrometry. Under optimal conditions, limits of detection and quantification in the ranges of 2.6–8.4 and 9.7–29 ng/kg, respectively, were obtained. The extraction recoveries and enrichment factors in the ranges of 70–89% and 350–445 were obtained, respectively.

Overview

Integrity signals

Registry

Crossref · 10.1002/jssc.201801016

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Metadata

Authors
Torbati, M., Farajzadeh, M. A., Mogaddam, M. R. A., & Torbati, M.
Affiliations
  • Tabriz University of Medical Sciences (IR)
  • University of Tabriz (IR)
Corresponding author
Mogaddam, Mohammad Reza Afshar
Venue
Journal of Separation Science
Publisher
Wiley
Published
2019-04-14
Volume
42
Issue
9
Pages
1768-1776
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W2917363055
Cited by
67
References
28
Citations by year
2026: 1 · 2025: 3 · 2024: 7 · 2023: 6 · 2022: 6 · 2021: 31 · 2020: 9 · 2019: 3
FWCI
6.86
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Separation Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
Tabriz University of Medical Sciences
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
Keywords
deep eutectic solvents, homogeneous liquid-liquid extraction, herbicides, tea, preconcentration, pesticide residues
MeSH terms
Food Contamination, Herbicides, Gas Chromatography-Mass Spectrometry, Syringes, Tea, Liquid-Liquid Extraction, Liquid Phase Microextraction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.