A robust LC–MS/MS assay with online cleanup for measurement of serum testosterone
Abstract
Accurate measurement of low levels of testosterone is critical for diagnosis and treatment of androgen disorders. The very low concentrations of testosterone in children, females, and males with androgen suppression therapies necessitate the use of mass spectrometry‐based methods. We aimed to develop a liquid chromatography with tandem mass spectrometry method with simplified sample preparation and online solid‐phase extraction cleanup to achieve enhanced precision, accuracy, robustness, and cost‐effectiveness. The assay was linear from 10 to 20 000 pg/mL with an analytical recovery of 93–104%. The total coefficient of variation was 2.5, 1.9, and 1.7% at concentration levels of 348, 5432, and 10 848 pg/mL, respectively. No significant carryover was observed from samples with concentrations up to 20 000 pg/mL. No significant interference was observed from androstenedione, dehydroepiandrosterone, epi‐testosterone, and estriol. Comparison with CDC Hormone Standardization program (HoSt) reference samples with defined values (n = 40) showed a Deming regression slope of 0.963, intercept of 28.06 pg/mL, standard error of estimate was 66.9, a correlation coefficient of 0.9996, and a mean bias of −0.6%. The method met the accuracy criteria by the CDC HoSt program. In addition, we achieved >12 000 injections on a single analytical column without significant performance deterioration due to the specific online solid‐phase extraction settings.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Mass spectrometry methods exhibit higher accuracy and lower variability than immunoassays, especially at low analyte concentrations.
“Mass spectrometry (MS) methods exhibit higher accuracy and lower variability than immunoassays, especially at low analyte concentrations.”
From Clinical Usefulness of Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry Method for Low Serum Testosterone Measurement (2023) · cites this paper as [3]
Cites
Rosner, W., Auchus, R. J., Azziz, R., Sluss, P. M., & Raff, H. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-1864 · Cited by 1,176 · see citing works
Androgen therapy in women: An Endocrine Society clinical practice guideline
Wierman, M. E., Basson, R., Davis, S. R., Khosla, S., Miller, K. K., Rosner, W., & Santoro, N. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-1121 · Cited by 301 · see citing works
Vesper, H. W., Bhasin, S., Wang, C., Tai, S. S., Dodge, L. A., Singh, R. J., Nelson, J., Ohorodnik, S., Clarke, N. J., Salameh, W. A., et al. (2009) · Steroids · doi:10.1016/j.steroids.2009.01.004 · Cited by 152 · see citing works
Yun, Y.-M., Botelho, J. C., Chandler, D. W., Katayev, A., Roberts, W. L., Stanczyk, F. Z., Vesper, H. W., Nakamoto, J. M., Garibaldi, L., Clarke, N. J., et al. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.186569 · Cited by 36 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Cho, S.-E., Han, J., Park, J.-H., Park, E., Kim, G. Y., Lee, J. H., Yi, A., Lee, S. G., Lee, E. H., & Yun, Y.-M. (2023) · Annals of Laboratory Medicine · doi:10.3343/alm.2023.43.1.19 · Cited by 3 · see citing works
- Authors
- Zhou, Y., & Wang, S.
- Affiliations
- Cleveland Clinic (US)
- Corresponding author
- Wang, Sihe
- ORCID
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2019-06-05
- Volume
- 42
- Issue
- 15
- Pages
- 2561-2568
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2945127529
- Cited by
- 4
- References
- 4
- Citations by year
- 2022: 2 · 2021: 1 · 2020: 1
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Separation Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hormonal and reproductive studies
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Keywords
- serum testosterone, LC-MS/MS assay, on-line solid-phase extraction, sample cleanup, androgen deprivation therapy, assay robustness, carryover, method validation
- MeSH terms
- Chromatography, Liquid, Humans, Testosterone, Solid Phase Extraction, Tandem Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review