Optimization of heteroatom doped graphene oxide by deep eutectic solvents and the application for pipette-tip solid-phase extraction of flavonoids
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
In order to improve the permeation and adsorption properties of graphene oxide, heteroatoms and deep eutectic solvent were introduced in this study. After being modified, the structural properties of graphene oxide were improved and the materials were applied to the determination of myricetin and rutin in tea sample by pipette-tip solid-phase extraction method. The materials were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, X-Ray diffractomer, energy dispersive spectroscopy, atomic force microscope, and specific surface area by Brunauer-Emmett-Teller N2 adsorption desorption analysis. Meanwhile, they were tested by static and dynamic adsorption. The result showed that the materials after modifying had better adsorption amount for myricetin and rutin than graphene oxide. The calibration graphs of myricetin and rutin in MeOH were linear over 0.10-500.00 μg/mL, and the limits of detection and quantification were in the range of 0.00546-0.0182 μg/mL and 0.00741-0.0247 μg/mL, respectively. A reliable analytical method was developed for recognition targets in tea sample by DES modified nitrogen-doped graphene oxide with satisfactory extraction recoveries (myricetin 99.77%, rutin 98.14%). It was potential for the rapid purification of myricetin and rutin in tea sample combined with the pipette-tip solid-phase extraction.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Finally, N-GO-DES was selected as the optimum adsorbent for this method, due to its permeability and high recoveries (that of myricetin was in the range of 70.61–99.77%, and rutin in between 76.58–98.14%) [57].”
From Microextraction Techniques with Deep Eutectic Solvents (2020) · cites this paper as [57]
Citations
Cites
Extraction techniques with deep eutectic solvents
Cunha, S. C., & Fernandes, J. O. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.05.001 · Cited by 760
Antioxidant and anti-inflammatory properties of flavonoids from lotus plumule
Chen, G.-L., Fan, M.-X., Wu, J.-L., Li, N., & Guo, M.-Q. (2019) · Food Chemistry · doi:10.1016/j.foodchem.2018.11.040 · Cited by 205
Wu, H., Chen, M., Fan, Y., Elsebaei, F., & Zhu, Y. (2011) · Talanta · doi:10.1016/j.talanta.2011.10.036 · Cited by 144
Permanent adsorption of organic solvents in graphite oxide and its effect on the thermal exfoliation
Barroso‐Bujans, F., Cerveny, S., Verdejo, R., Val, J. J. D., Alberdi, J. M., Alegría, Á., & Colmenero, J. (2009) · Carbon · doi:10.1016/j.carbon.2009.11.029 · Cited by 117
Gu, H., Chen, F., Zhang, Q., & Zang, J. (2016) · Journal of Chromatography B · doi:10.1016/j.jchromb.2016.01.045 · Cited by 72
Ocular toxicity of reduced graphene oxide or graphene oxide exposure in mouse eyes
An, W., Zhang, Y., Zhang, X., Li, K., Kang, Y., Akhtar, S., Sha, X., & Gao, L. (2018) · Experimental Eye Research · doi:10.1016/j.exer.2018.05.024 · Cited by 68
Wan, Y., Wang, M., Fu, Q., Wang, L., Wang, D., Zhang, K., Xia, Z., & Gao, D. (2018) · Journal of Chromatography B · doi:10.1016/j.jchromb.2018.08.033 · Cited by 65
Bharathidasan, P., Idris, M. B., Kim, D., Sivakkumar, S. R., & Devaraj, S. (2018) · FlatChem · doi:10.1016/j.flatc.2018.10.001 · Cited by 64
Fu, N., Li, L., Liu, K., Kim, C. K., Li, J., Zhu, T., Li, J., & Tang, B. (2019) · Talanta · doi:10.1016/j.talanta.2019.01.072 · Cited by 62
Self-citationXie, Z., Sun, Y., Lam, S. C., Zhao, M., Liang, Z., Yu, X., Yang, D., & Xu, X. (2014) · Journal of Separation Science · doi:10.1002/jssc.201301340 · Cited by 51
Cited by
Recent advances in micro- and nanomaterial-based adsorbents for pipette-tip solid-phase extraction
Sun, H., Feng, J., Han, S., Ji, X., Li, C., Feng, J., & Sun, M. H. (2021) · Microchimica Acta · doi:10.1007/s00604-021-04806-0 · Cited by 89
“For food samples, Tang and coworkers used chloramphenicol as the template and alcohol-based DES as the auxiliary functional monomer to prepare DES-MIPs [102].”
MethodInfluentialMicroextraction Techniques with Deep Eutectic Solvents
Plastiras, O.-E., Andreasidou, E., & Samanidou, V. (2020) · Molecules · doi:10.3390/molecules25246026 · Cited by 84
Natural Deep Eutectic Solvents in Extraction Science: Progress, Challenges, and Future Prospects
Suthar, K. J. (2025) · Separation Science Plus · doi:10.1002/sscp.70075 · Cited by 60
Tang, W., An, Y., & Row, K. H. (2020) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2020.112910 · Cited by 50
Application of deep eutectic solvents on extraction of flavonoids
Hao, Y., Pei, F., Huang, J., Li, G., & Zhong, C. (2024) · Journal of Separation Science · doi:10.1002/jssc.202300925 · Cited by 48
Siddiqui, A. S., Hayat, A., Nawaz, M. H., Ahmad, M. A., & Nasir, M. (2019) · Applied Surface Science · doi:10.1016/j.apsusc.2019.144695 · Cited by 46
Graphene-based nanocomposites in analytical extraction processes
Pena‐Pereira, F., Romero, V., de la Calle, I., Lavilla, I., & Bendicho, C. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116303 · Cited by 44
Liu, Y., Cao, S., Liu, Z., Wu, D., Luo, M., & Chen, Z. (2023) · Chemosphere · doi:10.1016/j.chemosphere.2023.138276 · Cited by 36
Sorbents modified by deep eutectic solvents in microextraction techniques
Makoś‐Chełstowska, P., & Gębicki, J. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117577 · Cited by 32
Recent advances of graphene-based sorptive materials in extraction: A review
Li, Y., Lan, S., & Zhu, T. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116319 · Cited by 29
Self-citationLan, S., Li, Y., Song, X. M., Zhu, T., & Yan, H. (2021) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2021.116532 · Cited by 23
Self-citationDramou, P., Wang, F., Sun, Y., Zhang, J., Yang, P., Liu, D., & He, H. (2022) · Applied Clay Science · doi:10.1016/j.clay.2021.106397 · Cited by 19
Li, G., & Row, K. H. (2020) · Journal of Separation Science · doi:10.1002/jssc.202000984 · Cited by 16
Jangizahi, J., & Hashemi, S. H. (2023) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067319.2023.2221177 · Cited by 15
Juan, Y. L., Dan, Z. X. C., Liao, Q. G., Wen, Z. D., & Guang, L. (2019) · Journal of Separation Science · doi:10.1002/jssc.201900871 · Cited by 14
Nanomaterials As Sorbents in Solid-Phase Extraction for Bioactive Compounds
Gutiérrez-Fernández, L., Andrés, M. P. S., & Diez-Pascual, A. M. (2024) · Separation and Purification Reviews · doi:10.1080/15422119.2024.2362401 · Cited by 12
Xiang, L., Huang, Q., Ding, Z., Yu, R., Zhao, Y., Liu, Z., Jiang, Y., & Liu, Y. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.167976 · Cited by 10
Wei, T., Wen, X. P., Wu, D., Shen, J., Wei, Y., & Wang, C. (2020) · Journal of Separation Science · doi:10.1002/jssc.202000275 · Cited by 10
Combinations of Nanomaterials and Deep Eutectic Solvents as Innovative Materials in Food Analysis
Santana‐Mayor, Á., Rodríguez‐Ramos, R., Socas‐Rodríguez, B., Afonso, M. M., & Palenzuela, J. A. (2021) · Processes · doi:10.3390/pr9122131 · Cited by 9
Li, K., Chen, J., Kang, S., & Lee, J. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.343494 · Cited by 7
Fan, B., Wei, J., Yang, J., Liu, Y., & Shuang, S. (2024) · Analytical Methods · doi:10.1039/d4ay01167h · Cited by 6
Deep Eutectic Solvents (DESs) in Green Sample Preparation
Ortega-Zamora, C., & González‐Sálamo, J. (2023) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781839166419-00212 · Cited by 2
Green nanomaterials for sorbent-based extraction techniques in food analysis
Gañán, J., Pérez‐Quintanilla, D., Morante‐Zarcero, S., & Sierra, I. (2023) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2023.09.014 · Cited by 2
Xiang, L., Wang, W., Chen, X., Yu, R., Liu, Z., Jiang, Y., Macedo, V. M. S., Soto, F. S., Zeb, S., & Liu, Y. (2026) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.6c07551
Metadata
- Authors
- Sun, L., Deng, Q., & Zhu, T.
- Affiliations
- Tianjin University of Technology (CN)
- Corresponding author
- Zhu, Tao
- ORCID
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2019-06-26
- Volume
- 42
- Issue
- 14
- Pages
- 2371-2378
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2944806446
- Cited by
- 23
- References
- 20
- Citations by year
- 2025: 2 · 2024: 5 · 2023: 4 · 2022: 1 · 2021: 5 · 2020: 4 · 2019: 2
- FWCI
- 1.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Separation Science (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Materials Science › Materials Chemistry › Graphene research and applications
- Keywords
- nitrogen-doped graphene oxide, deep eutectic solvents, heteroatom doping, pipette-tip solid-phase extraction, flavonoids, myricetin, rutin, tea samples, adsorption properties, preconcentration
- MeSH terms
- Flavonoids, Graphite, Particle Size, Rutin, Solvents, Surface Properties, Solid Phase Extraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.