The DOI matches its Crossref record; the references it cites are not checked yet.
Preparation of Zwitterionic Silica‐Based Sorbents for Simultaneous Extraction of Acidic and Basic Pharmaceuticals From Water Samples
Open accessAbstract
The sol‐gel approach was applied to develop three homemade silica sorbents. These sorbents where functionalized with mixed‐mode zwitterionic exchange groups using only one additive to introduce at once the strong cation‐ (sulfonic groups) and strong anion‐exchange (quaternary amines) moieties. The developed materials were applied for the solid‐phase extraction (SPE) of basic and acidic pharmaceuticals, and the sorbent functionalized with 2‐(methacryloxy)‐ethyldimethyl‐3‐(sulfopropyl)ammonium hydroxide was the best performing one. The optimal conditions for SPE were pH 5, a variable loading volume (ranging from 25 to 100 mL depending on the complexity of the sample) and elution volume with 5 mL of 1% NH 4 OH in MeOH. The method validation was carried out attending to apparent and relative recoveries, matrix effect, precision (intraday and interday), and detection and quantification limits. It can be highlighted that apparent recoveries were higher than 30% for most compounds and method detection limits were at the low ng/L. The validated method was applied to quantify the pharmaceuticals in environmental water samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
References 45 · Cited by 2
Research works printed but not linked: 46
- 10.1080/10408347.2017.1298987 · DOI
- 10.1002/jssc.201801299 · DOI
- 10.1002/jssc.202001177 · DOI
- 10.1002/jssc.202100654 · DOI
- 10.1016/j.chroma.2023.464518 · DOI
- 10.1002/jssc.202000129 · DOI
- 10.1002/jssc.202000047 · DOI
- 10.1002/jssc.201700881 · DOI
- 10.1016/j.chroma.2018.05.011 · DOI
- 10.1016/j.chroma.2018.02.004 · DOI
- 10.1080/10826076.2021.1958343 · DOI
- 10.1016/j.microc.2020.104672 · DOI
- 10.1016/j.aca.2020.03.053 · DOI
- 10.1016/j.chroma.2021.462165 · DOI
- 10.1016/j.talanta.2021.122375 · DOI
- 10.1016/j.aca.2021.338957 · DOI
- 10.1016/j.chroma.2018.06.042 · DOI
- 10.1016/j.chroma.2020.461645 · DOI
- 10.1016/j.chroma.2021.462715 · DOI
- 10.1016/j.chroma.2020.461348 · DOI
- 10.1016/j.aca.2021.338604 · DOI
- 10.1016/j.chroma.2022.463237 · DOI
- 10.1007/s00216-018-1037-3 · DOI
- 10.1016/j.chroma.2013.08.025 · DOI
- 10.1016/j.talanta.2023.124315 · DOI
- 10.1016/j.scitotenv.2021.149412 · DOI
- 10.1007/s00267-020-01275-8 · DOI
- 10.1016/j.jenvman.2017.04.101 · DOI
- 10.1016/j.chemosphere.2019.01.167 · DOI
- 10.1016/j.microc.2023.109619 · DOI
- 10.1016/j.chroma.2017.01.077 · DOI
- 10.1023/A:1015208328256 · DOI
- 10.1039/C5TA08024J · DOI
- 10.3390/polym11020192 · DOI
- 10.1016/j.sampre.2023.100074 · DOI
- 10.5740/jaoacint.12-121 · DOI
- 10.1007/s00216-017-0736-5 · DOI
- European Commission, 2021, Commission Implementing Regulation (EU) 2021/808 of 22 March 2021 on the Performance of Analytical Methods for Residues of Pharmacologically Active Substances Used in Food‐Producing Animals and on the Interpretation of Results as Well as on the Methods to, Official Journal of the European Union, 180, 84
- 10.1016/j.chroma.2020.461295 · DOI
- 10.1007/s11270-018-3845-7 · DOI
- 10.1007/s11356-016-7759-x · DOI
- 10.1016/j.chemosphere.2014.03.069 · DOI
- 10.1016/j.envpol.2020.114113 · DOI
- 10.1016/j.chroma.2013.12.012 · DOI
- 10.1007/s00128-019-02550-z · DOI
- 10.1007/s00216-010-4101-1 · DOI
Metadata
- Authors
- Moral, A., Borrull, F., Furton, K. G., Kabir, A., Fontanals, N., & Marcé, R. M.
- Affiliations
- Universitat Rovira i Virgili (ES)
- Florida International University (US)
- Corresponding author
- Fontanals, Núria
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2025-09
- Volume
- 48
- Issue
- 9
- Pages
- e70280-e70280
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- PMC
- PMC12454925
- OpenAlex
- W4414414359
- Cited by
- 2
- References
- 45
- Citations by year
- 2026: 2
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of Separation Science (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by-nc)
- Rovira & Virgili repository (submittedVersion, cc-by)
- Funders
- Universitat Rovira i Virgili (MCIN/AEI/10.13039/501100011033/, 2020PMF-PIPF-33)
- Agencia Estatal de Investigación (RED2022-134079-T, 501100011033, PID2020-114587GB-I00, 13039, .13039/501100011033, AEI/10)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Environmental Science › Pollution › Pharmaceutical and Antibiotic Environmental Impacts
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Keywords
- silica-based sorbents, mixed-mode solid-phase extraction, pharmaceuticals in water, sol-gel synthesis, sulfonic acid groups, quaternary amines, environmental water analysis, method validation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review