Microdebrider‐assisted versus radiofrequency‐assisted inferior turbinoplasty
The DOI matches its Crossref record.
Abstract
Objectives: The study aimed to evaluate the long‐term efficacy of microdebrider‐assisted inferior turbinoplasty (MAIT) compared to radiofrequency‐assisted inferior turbinoplasty (RAIT) for hypertrophic inferior turbinates. Study Design: Surgical outcomes were evaluated using the visual analogue scale, anterior rhinomanometry, and saccharin test results. Methods: From January 2001 to December 2006 inclusively, 120 patients with persistent allergic rhinitis, chronic nasal obstruction, and hypertrophic inferior turbinates were enrolled in this study, randomly classified, and underwent either MAIT (n = 60) or RAIT. Ten patients who did not have any nasal discomfort served as normal controls. Assessments (visual analogue scale, anterior rhinomanometry, and saccharin test) were conducted prior to surgery and 6 months, 1, 2, and 3 years subsequent to surgery. Results: Compared to preoperative values, the symptom scores (nasal obstruction, sneezing, rhinorrhea, and snoring), mean total nasal resistance, and mean saccharin transit time all improved significantly at 6 months, 1, 2, and 3 years after surgery in MAIT group (P < .05 for all). The same holds true for the RAIT group from 6 months up to 1 year (P < .05 for all), but no improvements from 2 to 3 years after were noted. The parameters between the two groups did not significantly differ 6 months after surgery, but was noted after 1 to 3 years (P < .05 for all). Conclusion: MAIT is more effective than RAIT at relieving nasal symptoms and decreasing total nasal resistance and saccharin transit time 1 to 3 years postoperatively in patients with persistent allergic rhinitis and who have substantial nasal obstruction. Laryngoscope, 119:414–418, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
International consensus statement on allergy and rhinology: Allergic rhinitis – 2023
Wise, S. K., Damask, C., Roland, L. T., Ebert, C., Levy, J. M., Lin, S., Luong, A., Rodriguez, K., Sedaghat, A. R., Toskala, E., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23090 · Cited by 507
Acevedo, J. L., Camacho, M., & Brietzke, S. E. (2015) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599815607211 · Cited by 54
Vijay Kumar, K., Kumar, S., & Garg, S. (2014) · Indian Journal of Otolaryngology and Head & Neck Surgery · doi:10.1007/s12070-013-0657-3 · Cited by 32
“It is reasonable to state that Group MD improved patients’ long-term symptoms more effectively than group RF [26].”
BackgroundAvashia, Y. J., Glener, A. D., & Marcus, J. R. (2022) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000009290 · Cited by 11
Metadata
- Authors
- Liu, C., Tan, C., Lee, F., Lin, K., & Huang, H.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2009-01-26
- Volume
- 119
- Issue
- 2
- Pages
- 414-418
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W1976195491
- Cited by
- 102
- References
- 0
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microdebrider‐assisted versus radiofrequency‐assisted inferior turbinoplasty. https://app.cochat.ai/papers/10.1002/lary.20088
- The paper
- Liu, C., Tan, C., Lee, F., Lin, K., & Huang, H. (2009). Microdebrider‐assisted versus radiofrequency‐assisted inferior turbinoplasty. The Laryngoscope. https://doi.org/10.1002/lary.20088
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.