CoChat

Inferior Turbinate classification system, grades 1 to 4: Development and validation study

Camacho, Macario, Zaghi, Soroush, Certal, Victor, Abdullatif, Jose, Means, Casey, Acevedo, Jason, Liu, Stanley, Brietzke, Scott E., Kushida, Clete A., Capasso, Robson · 2015 · The Laryngoscope
Cited by 113

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objectives/Hypothesis: To develop a validated inferior turbinate grading scale. Study Design: Development and validation study. Methods: Phase 1 development (alpha test) consisted of a proposal of 10 different inferior turbinate grading scales (>1,000 clinic patients). Phase 2 validation (beta test) utilized 10 providers grading 27 standardized endoscopic photos of inferior turbinates using two different classification systems. Phase 3 validation (pilot study) consisted of 100 live consecutive clinic patients (n = 200 inferior turbinates) who were each prospectively graded by 18 different combinations of two independent raters, and grading was repeated by each of the same two raters, two separate times for each patient. Results: In the development phase, 25% (grades 1–4) and 33% (grades 1–4) were the most useful systems. In the validation phase, the 25% classification system was found to be the best balance between potential clinical utility and ability to grade; the photo grading demonstrated a Cohen's kappa (κ) = 0.4671 ± 0.0082 (moderate inter‐rater agreement). Live‐patient grading with the 25% classification system demonstrated an overall inter‐rater reliability of 71.5% (95% confidence interval [CI]: 64.8–77.3), with overall substantial agreement (κ = 0.704 ± 0.028). Intrarater reliability was 91.5% (95% CI: 88.7–94.3). Distribution for the 200 inferior turbinates was as follows: 25% quartile = grade 1, 50% quartile (median) = grade 2, 75% quartile = grade 3, and 90% quartile = grade 4. Mean turbinate size was 2.22 (95% CI: 2.07‐2.34; standard deviation 1.02). Categorical κ was as follows: grade 1, 0.8541 ± 0.0289; grade 2, 0.7310 ± 0.0289; grade 3, 0.6997 ± 0.0289, and grade 4, 0.7760 ± 0.0289. Conclusions: The 25% (grades 1–4) inferior turbinate classification system is a validated grading scale with high intrarater and inter‐rater reliability. This system can facilitate future research by tracking the effect of interventions on inferior turbinates. Level of Evidence: 2c Laryngoscope, 125:296–302, 2015

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lary.24923

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 113

Metadata

Authors
Camacho, M., Zaghi, S., Certal, V., Abdullatif, J., Means, C., Acevedo, J., Liu, S., Brietzke, S. E., Kushida, C. A., & Capasso, R.
Venue
The Laryngoscope
Publisher
Wiley
Published
2014-09-12
Volume
125
Issue
2
Pages
296-302
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W2125559204
Cited by
113
References
3
FWCI
8.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.