Objectives: Middle ear surgery increasingly employs endoscopes as an adjunct to or replacement for the operative microscope. We provide a systematic review of endoscope applications in middle ear surgery with an emphasis on outcomes, including the need for conversion to microscope, audiometric findings, length of follow‐up, as well as disease‐specific outcomes. Data Sources: PubMed, Embase, and Cochrane CENTRAL database. Methods: A literature review was performed using the Preferred Reporting Items for Systematic Reviews and Meta‐Analysis recommendations. Articles were categorized based on study design, indication, and use of an endoscope either as an adjunct to or as a replacement for a microscope. Qualitative and descriptive analyses of studies and outcomes data were performed. Results: One‐hundred three articles met inclusion and exclusion criteria. Of the identified articles, 38 provided outcomes data. The majority of these studies were moderate quality, retrospective, case‐series reports. The indications for use of the endoscope were broad, with the most common being resection of cholesteatoma. In cholesteatoma surgery, endoscope approaches routinely identified residual cholesteatoma in primary and second‐look cases. Other outcomes, including robust audiometric data, operating room times, wound healing, and quality of life surveys were not well described. Conclusions: Endoscopes have consistently been used as an adjunct to the microscope to improve visualization of the tympanic cavity. Recent reports utilize the endoscope exclusively during surgical dissection; however, data comparing patient outcomes following the use of an endoscope to a microscope are lacking. Areas in need of additional research are highlighted. Level of Evidence: NA Laryngoscope, 125:1205–1214, 2015

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lary.25048

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 196

Metadata

Authors
Kozin, E. D., Gulati, S., Kaplan, A. B., Lehmann, A. E., Remenschneider, A. K., Landegger, L. D., Cohen, M. S., & Lee, D. J.
Venue
The Laryngoscope
Publisher
Wiley
Published
2014-11-24
Volume
125
Issue
5
Pages
1205-1214
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W1960075155
Cited by
196
References
2
FWCI
2.77
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Systematic review of outcomes following observational and operative endoscopic middle ear surgery. https://app.cochat.ai/papers/10.1002/lary.25048
The paper
Kozin, E. D., Gulati, S., Kaplan, A. B., Lehmann, A. E., Remenschneider, A. K., Landegger, L. D., Cohen, M. S., & Lee, D. J. (2015). Systematic review of outcomes following observational and operative endoscopic middle ear surgery. The Laryngoscope. https://doi.org/10.1002/lary.25048

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.