CoChat

Pepsin and oropharyngeal pH monitoring to diagnose patients with laryngopharyngeal reflux

Weitzendorfer, Michael, Antoniou, Stavros A., Schredl, Philipp, Witzel, Kai, Weitzendorfer, Isabella C., Majerus, Alexandra, Emmanuel, Klaus, Koch, Oliver O. · 2020 · The Laryngoscope
Cited by 70

The DOI matches its Crossref record.

Abstract

Objectives: The aim of this study was to compare the diagnostic accuracy of salivary pepsin with oropharyngeal pH monitoring using the Restech measurement system (Dx‐pH) for the diagnosis of laryngopharyngeal reflux (LPR). Study Design: Prospective cohort study. Methods: Seventy patients with primary symptoms related to LPR underwent gastroscopy, high‐resolution manometry, pH throughout 24‐hour monitoring (MII‐pH), and barium esophagography between October 2015 and May 2018. In addition, an ear, nose, and throat examination was performed, including assessment of Belafsky Reflux Finding Score (RFS). Clinical symptoms were evaluated with the Belafsky Reflux Symptom Index (RSI) and the Gastrointestinal Quality of Life Index (GIQLI). Simultaneous to MII‐pH, pepsin determination and Dx‐pH were performed. Results: Of 70 patients, 41 (58.6%) subjects with a pathological DeMeester score showed higher mean values of pepsin (mean value: 216 ng/mL, 95% confidence interval [CI]: 172 to 260), compared to patients with a normal DeMeester score (mean value: 161 ng/mL, 95% CI: 115 to 207). Salivary pepsin showed a specificity of 86.2% and sensitivity of 41.5% for diagnosing LPR using the optimal cutoff value of 216 ng/mL. Furthermore, a significant correlation between the values of salivary pepsin and the RSI score was seen in patients with pathological results in MII‐pH ( r = 0.344; P = 0.046). However, elevated Dx‐pH measurements showed no significant correlation with either MII‐pH, RSI score, RFS score, or GIQLI score, or with the results of pepsin measurement. Conclusion: Pepsin measurement in saliva could be an alternative tool to assist office‐based diagnosis of LPR, whereas Dx‐pH does not seem to be an adequate test. Level of Evidence: 2B Laryngoscope , 130:1780–1786, 2020

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lary.28320

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 35

  1. 10.1159/000210098 · doi:10.1159/000210098
  2. Campagnolo AM, 2014, Laryngopharyngeal reflux: diagnosis, treatment and latest research, Int Arch Otorhinolaryngol, 18, 184
  3. 10.1016/j.gtc.2012.11.004 · DOI
  4. 10.1067/mhn.2002.125760 · DOI · Paper page
  5. 10.1177/0194599819827488 · DOI · Paper page
  6. 10.1177/0003489400109S1003 · doi:10.1177/0003489400109s1003
  7. 10.1136/gutjnl-2014-307049 · DOI
  8. 10.1111/nmo.12109 · doi:10.1111/nmo.12109
  9. 10.1007/s11894-016-0486-0 · DOI
  10. 10.1177/2050640615617637 · doi:10.1177/2050640615617637
  11. 10.1542/peds.2007-0056 · DOI
  12. 10.1164/rccm.200610-1485OC · DOI · Paper page
  13. 10.1097/MLG.0b013e318064f177 · DOI
  14. 10.1097/01.mlg.0000172043.51871.d9 · DOI
  15. 10.1088/1752-7155/5/2/024001 · DOI
  16. 10.1111/nmo.12477 · DOI · Paper page
  17. 10.1002/bjs.1800820229 · DOI · Paper page
  18. 10.1055/s-2007-1004194 · DOI
  19. 10.1016/j.gie.2012.07.033 · DOI
  20. 10.1111/j.1572-0241.2006.00711.x · DOI · Paper page
  21. 10.1111/j.1572-0241.2004.04172.x · DOI · Paper page
  22. 10.1111/j.1365-2036.2005.02677.x · DOI · Paper page
  23. 10.1097/00005537-200106000-00009 · DOI · Paper page
  24. 10.1016/S0892-1997(02)00097-8 · DOI · Paper page
  25. 10.1097/00005537-200108000-00001 · DOI · Paper page
  26. 10.1007/s11605-009-0915-6 · DOI · Paper page
  27. 10.1007/s11894-016-0486-0 · DOI
  28. 10.1186/s12876-017-0667-9 · DOI
  29. 10.1007/s00405-017-4845-8 · DOI
  30. 10.1007/s11605-012-1866-x · doi:10.1007/s11605-012-1866-x
  31. 10.1111/nmo.12422 · DOI
  32. 10.1177/2050640613513016 · doi:10.1177/2050640613513016
  33. 10.1007/BF01535789 · DOI · Paper page
  34. 10.1002/lary.26018 · doi:10.1002/lary.26018
  35. 10.1002/lary.1991.101.s53.1 · DOI · Paper page

Cited by

Metadata

Authors
Weitzendorfer, M., Antoniou, S. A., Schredl, P., Witzel, K., Weitzendorfer, I. C., Majerus, A., Emmanuel, K., & Koch, O. O.
Affiliations
  • Department of Surgery Paracelsus Medical University Salzburg Austria
  • Department of Surgery School of Medicine, European University Cyprus Nicosia Cyprus
  • School of Medicine Johannes Kepler University (JKU) Linz Austria
Venue
The Laryngoscope
Publisher
Wiley
Published
2019-10-11
Volume
130
Issue
7
Pages
1780-1786
ISSN
  • 0023-852X
  • 1531-4995
Cited by
70
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.