The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Fluorescent and lasing whispering gallery mode microresonators for sensing applications
Open accessAbstract
Whispering gallery modes (WGMs) have been exploited for a broad range of sensing applications. However, the vast majority of WGM sensors consist of passive resonators, requiring complex interrogation systems to be employed, ultimately limiting their practicality. Active resonators containing a gain medium, allowing remote excitation and collection of the WGM‐modulated fluorescence spectra, have emerged as an alternative to passive resonators. Although research is still in its infancy, recent progress has reduced the performance gap between the two paradigms, fueled by the potential for new applications that could not previously be realized. Here, recent developments in sensors based on active WGM microresonators are reviewed, beginning with a discussion of the theory of fluorescence‐based and lasing WGMs, followed by a discussion of the variety of gain media, resonator architectures, and emerging sensing applications. We conclude with a discussion of the prospects and future directions for improving active WGM sensors.image
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vahala, K. J. (2003) · Nature · doi:10.1038/nature01939 · Cited by 4,878
Ultra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214
Improving FRET dynamic range with bright green and red fluorescent proteins
Lam, A. J., St-Pierre, F., Gong, Y., Marshall, J. D., Cranfill, P. J., Baird, M. A., McKeown, M. R., Wiedenmann, J., Davidson, M. W., Schnitzer, M. J., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2171 · Cited by 732
Nonlinear Optics and Crystalline Whispering Gallery Mode Cavities
Ilchenko, V. S., Savchenkov, A. A., Matsko, A. B., & Maleki, L. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.043903 · Cited by 473
Perovskite Microdisk Microlasers Self‐Assembled from Solution
Liao, Q., Hu, K., Zhang, H., Wang, X., Yao, J., & Fu, H. (2015) · Advanced Materials · doi:10.1002/adma.201500449 · Cited by 406
Cited by
Review of biosensing with whispering-gallery mode lasers
Toropov, N., Cabello, G., Serrano, M. P., Gutha, R. R., Rafti, M., & Vollmer, F. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00471-3 · Cited by 397
Nonlinear photonics with high-Q whispering-gallery-mode resonators
Lin, G., Coillet, A., & Chembo, Y. K. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000828 · Cited by 270
Metadata
- Authors
- Reynolds, T., Riesen, N., Meldrum, A., Fan, X., Hall, J. M. M., Monro, T. M., & François, A.
- Venue
- Laser & Photonics Reviews
- Publisher
- Wiley
- Published
- 2017-03
- Volume
- 11
- Issue
- 2
- ISSN
- 1863-8880 (ISSN-L)
- 1863-8899
- OpenAlex
- W2597387991
- Cited by
- 215
- References
- 5
- FWCI
- 9.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescent and lasing whispering gallery mode microresonators for sensing applications. https://app.cochat.ai/papers/10.1002/lpor.201600265
- The paper
- Reynolds, T., Riesen, N., Meldrum, A., Fan, X., Hall, J. M. M., Monro, T. M., & François, A. (2017). Fluorescent and lasing whispering gallery mode microresonators for sensing applications. Laser & Photonics Reviews. https://doi.org/10.1002/lpor.201600265
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.