The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optical properties of native and coagulated porcine liver tissue between 400 and 2400 nm
Abstract
Background and Objective: Laser induced thermotherapy (LITT) is a promising treatment for irresectable liver tumors. For predicting the effects of laser applications and optimizing irradiation planning in LITT, knowledge about light distribution in tissue, optical tissue properties (absorption, scattering, anisotropy, penetration depth) and their changes due to thermal denaturation is indispensable. Study Design/Materials and Methods: The optical parameters in healthy porcine liver were determined in the native state and after thermal coagulation using a double integrating sphere system in the wavelength range of 400–2400 nm. Results: Optical parameters showed significant fluctuations in the examined wavelength range mainly due to the water and hemoglobin content in the tissue. The greatest optical penetration depth of 7.46 mm was achieved at 1070 nm. After thermal coagulation, a clear increase in scattering and a slight decrease in absorption was found, which results in a decreased optical penetration depth. Conclusions: In order to ensure a safe and effective procedure, an adjustment of the laser power to the decreasing penetration depth is recommended during therapy. These results provide a better understanding of laser‐tissue interaction and may be helpful to investigators in the field of light dosimetry in liver tissue. Lasers Surg. Med. 29:205–212, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
Two-photon absorption properties of fluorescent proteins
Drobizhev, M., Makarov, N. S., Tillo, S. E., Hughes, T. E., & Rebane, A. (2011) · Nature Methods · doi:10.1038/nmeth.1596 · Cited by 675
Metadata
- Authors
- Ritz, J., Roggan, A., Isbert, C., Müller, G., Buhr, H. J., & Germer, C.
- Venue
- Lasers in Surgery and Medicine
- Publisher
- Wiley
- Published
- 2001-09
- Volume
- 29
- Issue
- 3
- Pages
- 205-212
- ISSN
- 0196-8092 (ISSN-L)
- 1096-9101
- OpenAlex
- W2005813498
- Cited by
- 248
- References
- 1
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical properties of native and coagulated porcine liver tissue between 400 and 2400 nm. https://app.cochat.ai/papers/10.1002/lsm.1134
- The paper
- Ritz, J., Roggan, A., Isbert, C., Müller, G., Buhr, H. J., & Germer, C. (2001). Optical properties of native and coagulated porcine liver tissue between 400 and 2400 nm. Lasers in Surgery and Medicine. https://doi.org/10.1002/lsm.1134
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.