The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Er:YAG laser ablation of tissue: Effect of pulse duration and tissue type on thermal damage
Abstract
The thermal damage caused by 2.94‐μm Er:YAG laser ablation of skin, cornea, aorta, and bone was quantified. The zone of residual thermal damage produced by normal‐spiking‐mode pulses (pulse duration ≈ 200 μs) and Q‐switched pulses (pulse duration ≈ 90 ns) was compared. Normal‐spiking‐mode pulses typically leave 10–50 μm of collagen damage at the smooth wall of the incisions; however, at the highest fluences (≈ 80 J/cm 2) tears were produced in cornea and aorta and as much as 100 μm of damaged collagen is found at the incision edge. Q‐switched pulses caused less thermal damage, typically 5–10 μm of damage in all tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harrison's Principles of Internal Medicine.
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-499_2 · Cited by 12,514
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,468
Bloom, W., & Fawcett, D. W. (1962) · Cited by 2,206
Photorefractive keratectomy: A technique for laser refractive surgery
Munnerlyn, C. R., Koons, S. J., & Marshall, J. (1988) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(88)80063-4 · Cited by 763
Srinivasan, R., & Banton, V. (1982) · Applied Physics Letters · doi:10.1063/1.93601 · Cited by 714
The multiplier method of Hestenes and Powell applied to convex programming
Rockafellar, R. T. (1973) · Journal of Optimization Theory and Applications · doi:10.1007/bf00934777 · Cited by 705
Harrison's Principles of Internal Medicine.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-93-1-155_1 · Cited by 593
Moritz, A. (1947) · Medical Entomology and Zoology · Cited by 465
Pulsed CO2 laser tissue ablation: Effect of tissue type and pulse duration on thermal damage
Walsh, J. T., Flotte, T. J., Anderson, R. R., & Deutsch, T. F. (1988) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900080204 · Cited by 372
Self-citationEr:YAG laser ablation of tissue: Measurement of ablation rates
Walsh, J. T., & Deutsch, T. F. (1989) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900090404 · Cited by 307
Self-citation
Cited by
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
Confocal Imaging–Guided Laser Ablation of Basal Cell Carcinomas: An Ex Vivo Study
Sierra, H., Cordova, M., Chen, C.-S. J., & Rajadhyaksha, M. (2015) · Journal of Investigative Dermatology · doi:10.1038/jid.2014.371 · Cited by 1,703
Vascular Dynamics of a Shape Memory Polymer Foam Aneurysm Treatment Technique
Ortega, J., Maitland, D., Wilson, T., Tsai, W., Savaş, Ö., & Saloner, D. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9358-y · Cited by 57
Complications of Ablative and Nonablative Lasers and Light Sources
Tanzi, E. L., & Alster, T. S. (2008) · Complications in Cutaneous Surgery · doi:10.1007/978-0-387-73152-0_13 · Cited by 6
Metadata
- Authors
- Walsh, J. T., Flotte, T. J., & Deutsch, T. F.
- Venue
- Lasers in Surgery and Medicine
- Publisher
- Wiley
- Published
- 1989-01
- Volume
- 9
- Issue
- 4
- Pages
- 314-326
- ISSN
- 0196-8092 (ISSN-L)
- 1096-9101
- OpenAlex
- W2150591237
- Cited by
- 478
- References
- 15
- FWCI
- 21.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Er:YAG laser ablation of tissue: Effect of pulse duration and tissue type on thermal damage. https://app.cochat.ai/papers/10.1002/lsm.1900090403
- The paper
- Walsh, J. T., Flotte, T. J., & Deutsch, T. F. (1989). Er:YAG laser ablation of tissue: Effect of pulse duration and tissue type on thermal damage. Lasers in Surgery and Medicine. https://doi.org/10.1002/lsm.1900090403
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.