The DOI matches its Crossref record.
Transient elastography for diagnosis of advanced fibrosis and portal hypertension in patients with hepatitis C recurrence after liver transplantation
Abstract
Recurrence of hepatitis C after liver transplantation (LT) is the main cause of graft loss and retransplantation. Frequent liver biopsies are essential to follow-up hepatitis C virus (HCV)-induced liver damage. However, liver biopsy is an invasive and expensive procedure. We evaluated prospectively the diagnostic accuracy of noninvasive measurement of liver stiffness (by transient elastography) to assess the severity of hepatitis C recurrence after LT. For this purpose, we included 124 HCV-infected liver transplant recipients who underwent 169 liver biopsies and 129 hepatic hemodynamic studies with determination of hepatic venous pressure gradient (HVPG). Simultaneously, patients underwent measurement of liver stiffness. Liver fibrosis was mild (F0-F1) in 96 cases (57%) and significant (F2-F4) in 73 (43%). HVPG was normal (<6 mm Hg) in 69 cases (54%) and elevated (>or=6 mm Hg) in 60 (46%). Using a liver stiffness cutoff value of 8.5 kilopascals, the sensitivity, specificity, negative predictive value, and positive predictive value for diagnosis of fibrosis >or=F2 were 90%, 81%, 79%, and 92%, respectively. The area under the curve (AUC) for diagnosis of fibrosis >or=F2, >or=F3 and F4 were 0.90, 0.93, and 0.98, respectively. There was a close direct correlation between liver stiffness and HVPG (Pearson coefficient, 0.84; P < 0.001) and the AUC for diagnosis of portal hypertension (HVPG >or=6 mm Hg) was 0.93. Importantly, none of the individuals with liver stiffness below the cutoff value had either bridging fibrosis (F3) or cirrhosis (F4) or significant portal hypertension (HVPG >or=10 mm Hg). In conclusion, determination of liver stiffness is an extremely valuable tool to assess the severity of HCV recurrence after LT and in reducing the need of follow-up liver biopsies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
Garcia‐Tsao, G., Friedman, S., Iredale, J., & Pinzani, M. (2010) · Hepatology · doi:10.1002/hep.23478 · Cited by 538
Liver stiffness: a novel parameter for the diagnosis of liver disease
Mueller, S. (2010) · Hepatic Medicine: Evidence and Research · doi:10.2147/hmer.s7394 · Cited by 434
Non invasive evaluation of portal hypertension using transient elastography
Castera, L., Pinzani, M., & Bosch, J. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2011.07.005 · Cited by 326
Self-citationBeyond scoring: a modern interpretation of disease progression in chronic liver disease
Rosselli, M., MacNaughtan, J., Jalan, R., & Pinzani, M. (2013) · Gut · doi:10.1136/gutjnl-2012-302826 · Cited by 96
Metadata
- Authors
- Carrión, J. A., Navasa, M., Bosch, J., Bruguera, M., Gilabert, R., & Forns, X.
- Venue
- Liver Transplantation
- Published
- 2006
- Volume
- 12
- Issue
- 12
- Pages
- 1791-1798
- ISSN
- 1527-6465 (ISSN-L)
- 1527-6473
- OpenAlex
- W1965906008
- Cited by
- 415
- References
- 0
- FWCI
- 21.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transient elastography for diagnosis of advanced fibrosis and portal hypertension in patients with hepatitis C recurrence after liver transplantation. https://app.cochat.ai/papers/10.1002/lt.20857
- The paper
- Carrión, J. A., Navasa, M., Bosch, J., Bruguera, M., Gilabert, R., & Forns, X. (2006). Transient elastography for diagnosis of advanced fibrosis and portal hypertension in patients with hepatitis C recurrence after liver transplantation. Liver Transplantation. https://doi.org/10.1002/lt.20857
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.