Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 415

The DOI matches its Crossref record.

Transient elastography for diagnosis of advanced fibrosis and portal hypertension in patients with hepatitis C recurrence after liver transplantation

Carrión, Jose A., Navasa, Miquel, Bosch, Jaume, Bruguera, Miquel, Gilabert, Rosa, Forns, Xavier·2006·Liver Transplantation

Abstract

Recurrence of hepatitis C after liver transplantation (LT) is the main cause of graft loss and retransplantation. Frequent liver biopsies are essential to follow-up hepatitis C virus (HCV)-induced liver damage. However, liver biopsy is an invasive and expensive procedure. We evaluated prospectively the diagnostic accuracy of noninvasive measurement of liver stiffness (by transient elastography) to assess the severity of hepatitis C recurrence after LT. For this purpose, we included 124 HCV-infected liver transplant recipients who underwent 169 liver biopsies and 129 hepatic hemodynamic studies with determination of hepatic venous pressure gradient (HVPG). Simultaneously, patients underwent measurement of liver stiffness. Liver fibrosis was mild (F0-F1) in 96 cases (57%) and significant (F2-F4) in 73 (43%). HVPG was normal (<6 mm Hg) in 69 cases (54%) and elevated (>or=6 mm Hg) in 60 (46%). Using a liver stiffness cutoff value of 8.5 kilopascals, the sensitivity, specificity, negative predictive value, and positive predictive value for diagnosis of fibrosis >or=F2 were 90%, 81%, 79%, and 92%, respectively. The area under the curve (AUC) for diagnosis of fibrosis >or=F2, >or=F3 and F4 were 0.90, 0.93, and 0.98, respectively. There was a close direct correlation between liver stiffness and HVPG (Pearson coefficient, 0.84; P < 0.001) and the AUC for diagnosis of portal hypertension (HVPG >or=6 mm Hg) was 0.93. Importantly, none of the individuals with liver stiffness below the cutoff value had either bridging fibrosis (F3) or cirrhosis (F4) or significant portal hypertension (HVPG >or=10 mm Hg). In conclusion, determination of liver stiffness is an extremely valuable tool to assess the severity of HCV recurrence after LT and in reducing the need of follow-up liver biopsies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lt.20857

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 415

Metadata

Authors
Carrión, J. A., Navasa, M., Bosch, J., Bruguera, M., Gilabert, R., & Forns, X.
Venue
Liver Transplantation
Published
2006
Volume
12
Issue
12
Pages
1791-1798
ISSN
  • 1527-6465 (ISSN-L)
  • 1527-6473
OpenAlex
W1965906008
Cited by
415
References
0
FWCI
21.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transient elastography for diagnosis of advanced fibrosis and portal hypertension in patients with hepatitis C recurrence after liver transplantation. https://app.cochat.ai/papers/10.1002/lt.20857
The paper
Carrión, J. A., Navasa, M., Bosch, J., Bruguera, M., Gilabert, R., & Forns, X. (2006). Transient elastography for diagnosis of advanced fibrosis and portal hypertension in patients with hepatitis C recurrence after liver transplantation. Liver Transplantation. https://doi.org/10.1002/lt.20857

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.