The DOI matches its Crossref record.
Biodegradable materials of polylactides, 4. Porous biomedical materials based on mixtures of polylactides and polyurethanes
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Degradation products of polyurethanes based on diisocyanates such as MDI and TDI are toxic.
“degradation products of polyurethanes based on diisocyanates such as 4,4'-methylenediphenyl diisocyanae (MDI) and toluene diisocyanate (TDI) are toxic”
From Biodegradable synthetic polymers for tissue engineering (2003) · cites this paper as Gogolewski and Pennings, 1982
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 23
- Halpern B. D., 1977, Encyclopedia of Polymer Science and Technology
- 10.1093/oxfordjournals.bmb.a071492 · DOI
- Kinley C. E., 1980, Surg., 21, 163
- Annis D., 1979, Shell Polymers, 3, 52
- Oppenheimer E. T., 1961, Cancer Res., 21, 132
- 10.1001/archsurg.1966.01330050143023 · DOI
- 10.1002/jbm.820050305 · DOI
- Schneider A. K., 1967, Chem. Abstr., 67, 116596m
- 10.1016/0032-3861(82)90176-8 · DOI
- S.Gogolewski A. J.Pennings J. Appl. Polym. Sci. in press
- 10.1007/978-1-4684-7239-4 · DOI
- 10.1007/978-1-4615-6737-0_12 · DOI
- 10.1002/macp.1981.020051981103 · DOI
- 10.1097/00002480-197201000-00009 · DOI
- Katz A. R., 1970, Surg. Gynecol. Obstet., 131, 701
- Hoffmann A. S., 1977, J. Appl. Polym. Sci., Polym. Symp., 31, 313
- 10.1016/0032-3861(81)90168-3 · DOI · Paper page
- 10.1002/jbm.820020109 · DOI
- 10.1002/polc.5070660125 · DOI
- 10.1002/jbm.820110103 · DOI
- 10.3109/10731197709118667 · DOI
- 10.1002/polc.5070660129 · DOI
- 10.1002/jbm.820140108 · DOI
Cited by
Sorted by citations
A Literature Review of Poly(Lactic Acid)
Garlotta, D. (2001) · Journal of Polymers and the Environment · doi:10.1023/a:1020200822435 · Cited by 3,707
Biodegradable synthetic polymers for tissue engineering
CSIRO Molecular Science, B. 1., & Gunatillake, P. (2003) · European Cells and Materials · doi:10.22203/ecm.v005a01 · Cited by 1,765
“For example, degradation products of polyurethanes based on diisocyanates such as 4,4’-methylenediphenyl diisocyanae (MDI) and toluene diisocyanate (TDI) are toxic (McGill and Motto, 1974; Gogolewski and Pennings, 1982).”
Background
Metadata
- Authors
- Gogolewski, S., & Pennings, A. J.
- Affiliations
- University of Groningen (NL)
- Corresponding author
- Pennings, Albert J.
- Venue
- Die Makromolekulare Chemie, Rapid Communications
- Publisher
- Wiley
- Published
- 1982-12-17
- Volume
- 3
- Issue
- 12
- Pages
- 839-845
- ISSN
- 0173-2803 (ISSN-L)
- OpenAlex
- W1595972865
- Cited by
- 83
- References
- 0
- Citations by year
- 2022: 1 · 2021: 2 · 2020: 3 · 2016: 3 · 2015: 1 · 2014: 1 · 2013: 1
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Die Makromolekulare Chemie Rapid Communications (publishedVersion)
- University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer Foaming and Composites
- Keywords
- polylactic acid, polyurethane, porous media, biodegradable polymers, polymer blends, biomedical materials
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review