The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Vibrational spectroscopy of bare and solvated ionic complexes of biological relevance
Abstract
The low density of ions in mass spectrometers generally precludes direct infrared (IR) absorption measurements. The IR spectrum of an ion can nonetheless be obtained by inducing photodissociation of the ion using a high‐intensity tunable laser. The emergence of free electron lasers (FELs) and recent breakthroughs in bench‐top lasers based on nonlinear optics have now made it possible to routinely record IR spectra of gas‐phase ions. As the energy of one IR photon is insufficient to cause dissociation of molecules and strongly bound complexes, two main experimental strategies have been developed to effect photodissociation. In infrared multiple‐photon dissociation (IR‐MPD) many photons are absorbed resonantly and their energy is stored in the bath of vibrational modes, leading to dissociation. In the “messenger” technique a weakly bound van der Waals atom is detached upon absorption of a single photon. Fundamental, historical, and practical aspects of these methods will be presented. Both of these approaches make use of very different methods of ion preparation and manipulation. While in IR‐MPD ions are irradiated in trapping mass spectrometers, the “messenger” technique is generally carried out in molecular beam instruments. The main focus of this review is the application of IR spectroscopy to biologically relevant molecular systems (amino acids, peptides, proteins). Particular issues that will be addressed here include gas‐phase zwitterions, the (chemical) structures of peptides and their collision‐induced dissociation (CID) products, IR spectra of gas‐phase proteins, and the chelation of metal–ligand complexes. Another growing area of research is IR spectroscopy on solvated clusters, which offer a bridge between the gas‐phase and solution environments. The development of state‐of‐the‐art computational approaches has gone hand‐in‐hand with advances in experimental techniques. The main advantage of gas‐phase cluster research, as opposed to condensed‐phase experiments, is that the systems of interest can be understood in detail and structural effects can be studied in isolation. It will be shown that IR spectroscopy of mass‐selected (bio)molecular systems is now well‐placed to address specific questions on the individual effect of charge carriers (protons and metal ions), as well as solvent molecules on the overall structure. © 2009 Wiley Periodicals, Inc., Mass Spec Rev 28:468–494, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Cited by
Seo, J., Hoffmann, W., Warnke, S., Bowers, M. T., Pagel, K., & von Helden, G. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201606029 · Cited by 132
Metadata
- Authors
- Polfer, N. C., & Oomens, J.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2009-02-24
- Volume
- 28
- Issue
- 3
- Pages
- 468-494
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W1993101493
- Cited by
- 415
- References
- 2
- FWCI
- 19.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vibrational spectroscopy of bare and solvated ionic complexes of biological relevance. https://app.cochat.ai/papers/10.1002/mas.20215
- The paper
- Polfer, N. C., & Oomens, J. (2009). Vibrational spectroscopy of bare and solvated ionic complexes of biological relevance. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.20215
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.