The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Techniques for phosphopeptide enrichment prior to analysis by mass spectrometry
Abstract
Mass spectrometry is the tool of choice to investigate protein phosphorylation, which plays a vital role in cell regulation and diseases such as cancer. However, low abundances of phosphopeptides and low degrees of phosphorylation typically necessitate isolation and concentration of phosphopeptides prior to MS analysis. This review discusses the enrichment of phosphopeptides with immobilized metal affinity chromatography, reversible covalent binding, and metal oxide affinity chromatography. Capture of phosphopeptides on TiO 2 seems especially promising in terms of selectivity and recovery, but the success of all methods depends on careful selection of binding, washing, and elution solutions. Enrichment techniques are complementary, such that a combination of methods greatly enhances the number of phosphopeptides isolated from complex samples. Development of a standard series of phosphopeptides in a highly complex mixture of digested proteins would greatly aid the comparison of different enrichment methods. Phosphopeptide binding to magnetic beads and on‐plate isolation prior to MALDI‐MS are emerging as convenient methods for purification of small (µL) samples. On‐plate enrichment can yield >70% recoveries of phosphopeptides in mixtures of a few digested proteins and can avoid sample‐handling steps, but this technique is likely limited to relatively simple samples such as immunoprecipitates. With recent advances in enrichment techniques in hand, MS analysis should provide important insights into phosphorylation pathways. © 2009 Wiley Periodicals, Inc., Mass Spec Rev 29:29–54, 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ATM and ATR Substrate Analysis Reveals Extensive Protein Networks Responsive to DNA Damage
Matsuoka, S., Ballif, B. A., Smogorzewska, A., McDonald, E. R., Hurov, K. E., Luo, J., Bakalarski, C. E., Zhao, Z., Solimini, N., Lerenthal, Y., et al. (2007) · Science · doi:10.1126/science.1140321 · Cited by 3,075
Cited by
Proteomics: Challenges, Techniques and Possibilities to Overcome Biological Sample Complexity
Chandramouli, K., & Qian, P.-Y. (2009) · Human Genomics and Proteomics · doi:10.4061/2009/239204 · Cited by 511
Targeted Quantitation of Proteins by Mass Spectrometry
Liebler, D. C., & Zimmerman, L. J. (2013) · Biochemistry · doi:10.1021/bi400110b · Cited by 363
Advances in mass spectrometry-based clinical biomarker discovery
Crutchfield, C. A., Thomas, S. N., Sokoll, L. J., & Chan, D. W. (2016) · Clinical Proteomics · doi:10.1186/s12014-015-9102-9 · Cited by 292
Ehrenshaft, M., Deterding, L. J., & Mason, R. P. (2015) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2015.08.003 · Cited by 158
Proteins and Proteoforms: New Separation Challenges
Regnier, F. E., & Kim, J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05007 · Cited by 36
Metadata
- Authors
- Dunn, J. D., Reid, G. E., & Bruening, M. L.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2009-03-04
- Volume
- 29
- Issue
- 1
- Pages
- 29-54
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2107779633
- Cited by
- 213
- References
- 1
- FWCI
- 10.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.