The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Fourier transform ion cyclotron resonance (FT ICR) mass spectrometry: Theory and simulations
Abstract
Fourier transform ion cyclotron resonance (FT ICR) mass spectrometer offers highest resolving power and mass accuracy among all types of mass spectrometers. Its unique analytical characteristics made FT ICR important tool for proteomics, metabolomics, petroleomics, and investigation of complex mixtures. Signal acquisition in FT ICR MS takes long time (up to minutes). During this time ion–ion interaction considerably affects ion motion and result in decreasing of the resolving power. Understanding of those effects required complicated theory and supercomputer simulations but culminated in the invention of the ion trap with dynamic harmonization which demonstrated the highest resolving power ever achieved. In this review we summarize latest achievements in theory and simulation of FT ICR mass spectrometers. © 2014 Wiley Periodicals, Inc. Mass Spec Rev 35:219–258, 2016.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367 · cited 1×
“The dynamics of single particles inside the FTICR trap was analyzed by many groups in both FTICR and single charged particle physics communities (Brown & Gabrielse, 1986; Gabrielse, Haarsma, & Rolston, 1989; Huang et al., 1994; Naito & Inoue, 1994; Mitchell & Smith, 1995, 1996; Rainville, Thompson,…”
MethodBirdsall, C. K. (1991) · IEEE Transactions on Plasma Science · doi:10.1109/27.106800 · Cited by 1,363
Open-endcap Penning traps for high precision experiments
Gabrielse, G., Haarsma, L., & Rolston, S. L. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85027-x · Cited by 288
Cited by
Directed Evolution: Methodologies and Applications
Wang, Y., Xue, P., Cao, M., Yu, T., Lane, S. T., & Zhao, H. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00260 · Cited by 719
Mass spectrometry‐based plant metabolomics: Metabolite responses to abiotic stress
Jorge, T. F., Rodrigues, J. A., Caldana, C., Schmidt, R., van Dongen, J. T., Thomas‐Oates, J., & António, C. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21449 · Cited by 376
Proteins in Art, Archaeology, and Paleontology: From Detection to Identification
Dallongeville, S., Garnier, N., Rolando, C., & Tokarski, C. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00037 · Cited by 172
Metadata
- Authors
- Nikolaev, E. N., Kostyukevich, Y. I., & Vladimirov, G. N.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2014-02-10
- Volume
- 35
- Issue
- 2
- Pages
- 219-258
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W1703799520
- Cited by
- 201
- References
- 4
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.