Recent advances in LC‐MS‐based metabolomics for clinical biomarker discovery
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The employment of liquid chromatography‐mass spectrometry (LC‐MS) untargeted and targeted metabolomics has led to the discovery of novel biomarkers and improved the understanding of various disease mechanisms. Numerous strategies have been reported to expand the metabolite coverage in LC‐MS‐untargeted and targeted metabolomics. To improve the sensitivity of low‐abundance or poor‐ionized metabolites for reducing the amount of clinical sample, chemical derivatization methods are used to target different functional groups. Proper sample preparation is beneficial for reducing the matrix effect, maintaining the stability of the LC‐MS system, and increasing the metabolite coverage. Machine learning has recently been integrated into the workflow of LC‐MS metabolomics to accelerate metabolite identification and data‐processing automation, and increase the accuracy of disease classification and clinical outcome prediction. Due to the rapidly growing utility of LC‐MS metabolomics in discovering disease markers, this review will address the recent advances in the field and offer perspectives on various strategies for expanding metabolite coverage, chemical derivatization, sample preparation, clinical disease markers, and machining learning for disease modeling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From local explanations to global understanding with explainable AI for trees
Lundberg, S. M., Erion, G., Chen, H., DeGrave, A., Prutkin, J. M., Nair, B., Katz, R., Himmelfarb, J., Bansal, N., & Lee, S.-I. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-019-0138-9 · Cited by 10,551
Bruce, S. J., Tavazzi, I., Parisod, V., Rezzi, S., Kochhar, S., & Guy, P. A. (2009) · Analytical Chemistry · doi:10.1021/ac8024569 · Cited by 321
New software tools, databases, and resources in metabolomics: updates from 2020
Misra, B. B. (2021) · Metabolomics · doi:10.1007/s11306-021-01796-1 · Cited by 227
Perakakis, N., Polyzos, S. A., Yazdani, A., Sala-Vila, A., Kountouras, J., Anastasilakis, A. D., & Mantzoros, C. S. (2019) · Metabolism · doi:10.1016/j.metabol.2019.154005 · Cited by 137
Plasma steroid metabolome profiling for the diagnosis of adrenocortical carcinoma
Schweitzer, S., Kunz, M., Kurlbaum, M., Vey, J., Kendl, S., Deutschbein, T., Hahner, S., Fassnacht, M., Dandekar, T., & Kroiss, M. (2019) · European Journal of Endocrinology · doi:10.1530/eje-18-0782 · Cited by 85
Metadata
- Authors
- Chen, C., Lee, D., Yu, J., Lin, Y., & Lin, T.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2022-05-29
- Volume
- 42
- Issue
- 6
- Pages
- 2349-2378
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W4281713928
- Cited by
- 170
- References
- 5
- FWCI
- 8.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent advances in LC‐MS‐based metabolomics for clinical biomarker discovery. https://app.cochat.ai/papers/10.1002/mas.21785
- The paper
- Chen, C., Lee, D., Yu, J., Lin, Y., & Lin, T. (2023). Recent advances in LC‐MS‐based metabolomics for clinical biomarker discovery. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.21785
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.