Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 211

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Parkinson's disease is overdiagnosed clinically at baseline in diagnostically uncertain cases: A 3‐year European multicenter study with repeat [ 123 I]FP‐CIT SPECT

Open access
Marshall, Vicky L., Reininger, Cornelia B., Marquardt, Moritz, Patterson, Jim, Hadley, Donald M., Oertel, Wolfgang H., Benamer, Hani T.S., Kemp, Paul, Burn, David, Tolosa, Eduardo, Kulisevsky, Jamie, Cunha, Luis, Costa, Durval, Booij, Jan, Tatsch, Klaus, Chaudhuri, K. Ray, Ulm, Gudrun, Pogarell, Oliver, Höffken, Helmut, Gerstner, Anja, Grosset, Donald G. · 2009 · Movement Disorders

Abstract

Overdiagnosis of Parkinson's disease (PD) is suggested by specialist review of community diagnosis, and in postmortem studies. In specialist centers 4 to 15% of patients entered into clinical trials as early PD do not have functional imaging support for a PD diagnosis. In a European multicenter, prospective, longitudinal study, we compared clinical diagnosis with functional SPECT imaging using [ 123 I]FP‐CIT (DaTSCAN™, GE Healthcare). Repeat observations were performed over 3 years in patients with tremor and/or parkinsonism in whom there was initial diagnostic uncertainty between degenerative parkinsonism and nondegenerative tremor disorders. Video‐recording of clinical features was scored independently of functional imaging results by two blinded clinicians at 36 months (= gold standard clinical diagnosis). Three readers, unaware of the clinical diagnosis, classified the images as normal or abnormal by visual inspection. The main endpoint was the sensitivity and specificity of SPECT imaging at baseline compared with the gold standard. In 99 patients completing the three serial assessments, on‐site clinical diagnosis overdiagnosed degenerative parkinsonism at baseline in diagnostically uncertain cases compared with the gold standard clinical diagnosis (at 36 months), the latter giving a sensitivity of 93% and specificity of 46%. The corresponding baseline [ 123 I]FP‐CIT SPECT results showed a mean sensitivity of 78% and a specificity of 97%. Inter‐reader agreement for rating scans as normal or abnormal was high (Cohen's $\hat{\kappa}$ = 0.94–0.97). © 2008 Movement Disorder Society

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mds.22108

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Marshall, V. L., Reininger, C. B., Marquardt, M., Patterson, J., Hadley, D. M., Oertel, W. H., Benamer, H. T. S., Kemp, P., Burn, D., Tolosa, E., Kulisevsky, J., Cunha, L., Costa, D., Booij, J., Tatsch, K., Chaudhuri, K. R., Ulm, G., Pogarell, O., Höffken, H., Gerstner, A., & Grosset, D. G.
Venue
Movement Disorders
Publisher
Wiley
Published
2009-03-15
Volume
24
Issue
4
Pages
500-508
ISSN
  • 0885-3185 (ISSN-L)
  • 1531-8257
OpenAlex
W2009889181
Cited by
211
References
1
FWCI
8.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.