CoChat

Relationship between various clinical outcome assessments in patients with blepharospasm

Jankovic, Joseph, Kenney, Christopher, Grafe, Susanne, Goertelmeyer, Roman, Comes, George · 2009 · Movement Disorders
Cited by 167

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

The objective was to analyze the metric properties of the Jankovic Rating Scale (JRS) and a self‐rating patient response outcome scale, the Blepharospasm Disability Index (BSDI©), in blepharospasm patients. Data from a randomized, double‐blind, active‐control clinical trial in 300 patients with blepharospasm treated with either botulinum toxin type A (Botox®) or NT201 (Xeomin®) were used to evaluate the metric properties of the JRS and the BSDI compared with the Patient Evaluation of Global Response (PEGR) and Global Assessment Scale (GAS). The internal consistency of the BSDI was high, Cronbach's Alpha = 0.88, and the retest reliability of the BSDI single items was adequate, Spearman's rank coefficient = 0.453 < r < 0.595. The correlation between JRS sum score and BSDI weighted mean score was r = 0.487 (baseline) and r = 0.737 (control visit), respectively. Using the GAS and PEGR, the results suggest that a change of 2 points in the JRS and of 0.7 points in the BSDI are clinically meaningful. JRS and BSDI are objective indicators of clinical efficacy as suggested by their good validity when compared with physicians' and patients' rating scales. Both, JRS and BSDI, can be used to reliably assess blepharospasm in treatment trials. © 2008 Movement Disorder Society

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mds.22368

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

  • Dystonia rating scales: Critique and recommendations

    Albanese, A., Sorbo, F. D., Comella, C., Jinnah, H. A., Mink, J. W., Post, B., Vidailhet, M., Volkmann, J., Warner, T. T., Leentjens, A. F. G., et al. (2013) · Movement Disorders · doi:10.1002/mds.25579 · Cited by 201

    “The BSDI showed high internal consistency and the retest reliability of the single items was adequate.(9) The BSDI total score was found to correlate moderately with the Jankovic Rating Scale score.”
    Method
  • Blepharospasm 40 years later

    Defazio, G., Hallett, M., Jinnah, H. A., Conte, A., & Berardelli, A. (2017) · Movement Disorders · doi:10.1002/mds.26934 · Cited by 171

    “Historically, the most widely used severity scale is the Jankovic Rating Scale, which includes 2 subscales (both based on a 5-point grading system) that measure the intensity and frequency of eyelid spasms.(58) Although the Jankovic Rating Scale displays excellent internal consistency, data on its reliability and othe…”
    BackgroundMethod

See all 167

Metadata

Authors
Jankovic, J., Kenney, C., Grafe, S., Goertelmeyer, R., & Comes, G.
Venue
Movement Disorders
Publisher
Wiley
Published
2009-02-15
Volume
24
Issue
3
Pages
407-413
ISSN
  • 0885-3185 (ISSN-L)
  • 1531-8257
OpenAlex
W1760472848
Cited by
167
References
22
FWCI
2.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relationship between various clinical outcome assessments in patients with blepharospasm. https://app.cochat.ai/papers/10.1002/mds.22368
The paper
Jankovic, J., Kenney, C., Grafe, S., Goertelmeyer, R., & Comes, G. (2009). Relationship between various clinical outcome assessments in patients with blepharospasm. Movement Disorders. https://doi.org/10.1002/mds.22368

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.