Goetz, Christopher G., Stebbins, Glenn T., Wolff, David, DeLeeuw, William, Bronte‐Stewart, Helen, Elble, Rodger, Hallett, Mark, Nutt, John, Ramig, Lorraine, Sanger, Terence, Wu, Allan D., Kraus, Peter H., Blasucci, Lucia M., Shamim, Ejaz A., Sethi, Kapil D., Spielman, Jennifer, Kubota, Ken, Grove, Andrew S., Dishman, Eric, Taylor, C. Barr · 2009 · Movement Disorders
Cited by 152

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We tested the feasibility of a computer based at‐home testing device (AHTD) in early‐stage, unmedicated Parkinson's disease (PD) patients over 6 months. We measured compliance, technical reliability, and patient satisfaction to weekly assessments of tremor, small and large muscle bradykinesia, speech, reaction/movement times, and complex motor control. relative to the UPDRS motor score. The AHTD is a 6.5″ × 10″ computerized assessment battery. Data are stored on a USB memory stick and sent by internet to a central data repository as encrypted data packets. Although not designed or powered to measure change, the study collected data to observe patterns relative to UPDRS motor scores. Fifty‐two PD patients enrolled, and 50 completed the 6 month trial, 48 remaining without medication. Patients complied with 90.6% of weekly 30‐minute assessments, and 98.5% of data packets were successfully transmitted and decrypted. On a 100‐point scale, patient satisfaction with the program at study end was 87.2 (range: 80–100). UPDRS motor scores significantly worsened over 6 months, and trends for worsening over time occurred for alternating finger taps (P = 0.08), tremor (P = 0.06) and speech (P = 0.11). Change in tremor was a significant predictor of change in UPDRS (P = 0.047) and was detected in the first month of the study. This new computer‐based technology offers a feasible format for assessing PD‐related impairment from home. The high patient compliance and satisfaction suggest the feasibility of its incorporation into larger clinical trials, especially when travel is difficult and early changes or frequent data collection are considered important to document. © 2008 Movement Disorder Society

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mds.22379

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 152

Metadata

Authors
Goetz, C. G., Stebbins, G. T., Wolff, D., DeLeeuw, W., Bronte‐Stewart, H., Elble, R., Hallett, M., Nutt, J., Ramig, L., Sanger, T., Wu, A. D., Kraus, P. H., Blasucci, L. M., Shamim, E. A., Sethi, K. D., Spielman, J., Kubota, K., Grove, A. S., Dishman, E., & Taylor, C. B.
Venue
Movement Disorders
Publisher
Wiley
Published
2009-03-15
Volume
24
Issue
4
Pages
551-556
ISSN
  • 0885-3185 (ISSN-L)
  • 1531-8257
OpenAlex
W1987349122
Cited by
152
References
1
FWCI
4.71
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Testing objective measures of motor impairment in early Parkinson's disease: Feasibility study of an at‐home testing device. https://app.cochat.ai/papers/10.1002/mds.22379
The paper
Goetz, C. G., Stebbins, G. T., Wolff, D., DeLeeuw, W., Bronte‐Stewart, H., Elble, R., Hallett, M., Nutt, J., Ramig, L., Sanger, T., Wu, A. D., Kraus, P. H., Blasucci, L. M., Shamim, E. A., Sethi, K. D., Spielman, J., Kubota, K., Grove, A. S., Dishman, E., & Taylor, C. B. (2009). Testing objective measures of motor impairment in early Parkinson's disease: Feasibility study of an at‐home testing device. Movement Disorders. https://doi.org/10.1002/mds.22379

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.