Objective detection of subtle freezing of gait episodes in Parkinson's disease
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Freezing of gait (FOG) is a clinically defined phenomenon of Parkinson's disease (PD). Recent evidence suggests that subtle FOG episodes can be elicited in a gait laboratory using suddenly appearing obstacles during treadmill walking. We evaluated which quantitative gait parameters identify such subtle FOG episodes. We included 10 PD patients with FOG, 10 PD patients without FOG, and 10 controls. Subjects walked on a motorized treadmill while avoiding unexpectedly appearing obstacles. Treadmill walking was videotaped, and FOG episodes were identified by two independent experts. Gait was also analyzed using detailed kinematics. Knee joint signals were processed using time–frequency analysis with combinations of sliding fast Fourier transform and wavelets transform. Twenty FOG episodes occurred during treadmill walking in 5 patients (all with clinically certified FOG), predominantly in relation to obstacle avoidance. FOG was brief when it occurred just before or after obstacle crossing and was characterized by short, rapid steps. Frequency analysis showed a typical qualitative pattern: before the FOG episode an increase in dominant frequency in the 0 to 3 Hz band (festination), followed by decreased power in 0 to 3 Hz band and an increased power in the 3 to 8 Hz band during the FOG episode. This pattern led to an increased FOG index as a qualitative measure. These approaches detected even very brief FOG with acceptable sensitivity (75–83%) and specificity (>95%). We conclude that time–frequency analysis is an appropriate approach to detect brief and subtle FOG episodes. Future work will need to decide whether this approach can support or even replace expert clinical opinion. © 2010 Movement Disorder Society
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ambulatory monitoring of freezing of gait in Parkinson’s disease
Moore, S. T., MacDougall, H. G., & Ondo, W. G. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.08.023 · Cited by 526 · cited 4×
“5 to 3 Hz band.(13) Despite these promising findings, the question remains which of the previously identified factors (increased cadence, decreased step length, and highfrequency oscillations of the legs) are most relevant to detect FOG.”
BackgroundMethodResultInfluentialNieuwboer, A., Dom, R., De Weerdt, W., Desloovere, K., Fieuws, S., & Broens‐Kaucsik, E. (2001) · Movement Disorders · doi:10.1002/mds.1206 · Cited by 320 · cited 3×
“This difference is likely explained by the fact that the PD patients in our study were less severely impaired compared with previous studies.(9,11,13) In addition, the treadmill and the obstacles may have acted as cues to overcome the episode.”
BackgroundResult
Cited by
Freezing of gait: moving forward on a mysterious clinical phenomenon
Nutt, J. G., Bloem, B. R., Giladi, N., Hallett, M., Horak, F. B., & Nieuwboer, A. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70143-0 · Cited by 1,304
Self-citationQuantitative wearable sensors for objective assessment of Parkinson's disease
Maetzler, W., Domingos, J., Srulijes, K., Ferreira, J. J., & Bloem, B. R. (2013) · Movement Disorders · doi:10.1002/mds.25628 · Cited by 374
“With a frequency-based approach that has previously been shown to detect FOG accurately in PD,(40) even very subtle FOG episodes could be detected with acceptable sensitivity and high specificity, compared to judgment by 2 movement disorders specialists in a video analysis.(39) The detection of such subtle FOG is pote…”
MethodResultSelf-citationRodríguez-Martín, D., Samà, A., Pérez-López, C., Català, A., Moreno Arostegui, J. M., Cabestany, J., Bayés, À., Alcaine, S., Mestre, B., Prats, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171764 · Cited by 237
Online Detection of Freezing of Gait with Smartphones and Machine Learning Techniques
Mazilu, S., Hardegger, M., Zhu, Z., Roggen, D., Troester, G., Plotnik, M., & Hausdorff, J. (2012) · Proceedings of the 6th International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth.2012.248680 · Cited by 231
“Delval and collegues [24] collected data from PD patients wearing goniometers, monitorized while walking on a treadmill.”
Zach, H., Janssen, A. M., Snijders, A. H., Delval, A., Ferraye, M. U., Auff, E., Weerdesteyn, V., Bloem, B. R., & Nonnekes, J. (2015) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2015.09.051 · Cited by 97
“Interestingly, several studies recently evaluated the use of wearable accelerometers to detect FOG automatically [2,11,12].”
BackgroundSelf-citation
Metadata
- Authors
- Delval, A., Snijders, A. H., Weerdesteyn, V., Duysens, J. E., Defebvre, L., Giladi, N., & Bloem, B. R.
- Venue
- Movement Disorders
- Publisher
- Wiley
- Published
- 2010-08-15
- Volume
- 25
- Issue
- 11
- Pages
- 1684-1693
- ISSN
- 0885-3185 (ISSN-L)
- 1531-8257
- OpenAlex
- W2127199892
- Cited by
- 106
- References
- 2
- FWCI
- 16.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Objective detection of subtle freezing of gait episodes in Parkinson's disease. https://app.cochat.ai/papers/10.1002/mds.23159
- The paper
- Delval, A., Snijders, A. H., Weerdesteyn, V., Duysens, J. E., Defebvre, L., Giladi, N., & Bloem, B. R. (2010). Objective detection of subtle freezing of gait episodes in Parkinson's disease. Movement Disorders. https://doi.org/10.1002/mds.23159
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.