The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
AAPM TG 158: Measurement and calculation of doses outside the treated volume from external‐beam radiation therapy
Open accessAbstract
The introduction of advanced techniques and technology in radiotherapy has greatly improved our ability to deliver highly conformal tumor doses while minimizing the dose to adjacent organs at risk. Despite these tremendous improvements, there remains a general concern about doses to normal tissues that are not the target of the radiation treatment; any “nontarget” radiation should be minimized as it offers no therapeutic benefit. As patients live longer after treatment, there is increased opportunity for late effects including second cancers and cardiac toxicity to manifest. Complicating the management of these issues, there are unique challenges with measuring, calculating, reducing, and reporting nontarget doses that many medical physicists may have limited experience with. Treatment planning systems become dramatically inaccurate outside the treatment field, necessitating a measurement or some other means of assessing the dose. However, measurements are challenging because outside the treatment field, the radiation energy spectrum, dose rate, and general shape of the dose distribution (particularly the percent depth dose) are very different and often require special consideration. Neutron dosimetry is also particularly challenging, and common errors in methodology can easily manifest as errors of several orders of magnitude. Task Group 158 was, therefore, formed to provide guidance for physicists in terms of assessing and managing nontarget doses. In particular, the report: (a) highlights major concerns with nontarget radiation; (b) provides a rough estimate of doses associated with different treatment approaches in clinical practice; (c) discusses the uses of dosimeters for measuring photon, electron, and neutron doses; (d) discusses the use of calculation techniques for dosimetric evaluations; (e) highlights techniques that may be considered for reducing nontarget doses; (f) discusses dose reporting; and (g) makes recommendations for both clinical and research practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
MCNP-A General Monte Carlo N-Particle Transport Code
Briesmeister, J. F. (1993) · Cited by 5,110
Risk of Ischemic Heart Disease in Women after Radiotherapy for Breast Cancer
Darby, S. C., Ewertz, M., McGale, P., Bennet, A. M., Blom-Goldman, U., Brønnum, D., Correa, C., Cutter, D., Gagliardi, G., Gigante, B., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1209825 · Cited by 3,974
Chronic Health Conditions in Adult Survivors of Childhood Cancer
Oeffinger, K. C., Mertens, A. C., Sklar, C. A., Kawashima, T., Hudson, M. M., Meadows, A. T., Friedman, D. L., Marina, N., Hobbie, W., Kadan-Lottick, N. S., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmsa060185 · Cited by 3,597
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,753
Recommendations of the International Commission on Radiological Protection
(1959) · Health Physics · doi:10.1097/00004032-195901000-00001 · Cited by 1,703
Radiation-induced second cancers: the impact of 3D-CRT and IMRT
Hall, E. J., & Wuu, C.-S. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00073-7 · Cited by 1,301
Self-citationPreston, D. L., Shimizu, Y., Pierce, D. A., Suyama, A., & Mabuchi, K. (2003) · Radiation Research · doi:10.1667/rr3049 · Cited by 1,172
Metadata
- Authors
- Kry, S. F., Bednarz, B., Howell, R. M., Dauer, L., Followill, D., Klein, E., Paganetti, H., Wang, B., Wuu, C., & George Xu, X.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2017-08-20
- Volume
- 44
- Issue
- 10
- Pages
- e391-e429
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2728421336
- Cited by
- 307
- References
- 123
- FWCI
- 21.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AAPM TG 158: Measurement and calculation of doses outside the treated volume from external‐beam radiation therapy. https://app.cochat.ai/papers/10.1002/mp.12462
- The paper
- Kry, S. F., Bednarz, B., Howell, R. M., Dauer, L., Followill, D., Klein, E., Paganetti, H., Wang, B., Wuu, C., & George Xu, X. (2017). AAPM TG 158: Measurement and calculation of doses outside the treated volume from external‐beam radiation therapy. Medical Physics. https://doi.org/10.1002/mp.12462
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.