CoChat

Radiomics analysis of pulmonary nodules in low‐dose CT for early detection of lung cancer

Open access
Choi, Wookjin, Oh, Jung Hun, Riyahi, Sadegh, Liu, Chia‐Ju, Jiang, Feng, Chen, Wengen, White, Charles, Rimner, Andreas, Mechalakos, James G., Deasy, Joseph O., Lu, Wei · 2018 · Medical Physics
Cited by 152

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Purpose: To develop a radiomics prediction model to improve pulmonary nodule (PN) classification in low‐dose CT. To compare the model with the American College of Radiology (ACR) Lung CT Screening Reporting and Data System (Lung‐RADS) for early detection of lung cancer. Methods: We examined a set of 72 PN s (31 benign and 41 malignant) from the Lung Image Database Consortium image collection (LIDC‐IDRI). One hundred three CT radiomic features were extracted from each PN. Before the model building process, distinctive features were identified using a hierarchical clustering method. We then constructed a prediction model by using a support vector machine (SVM) classifier coupled with a least absolute shrinkage and selection operator (LASSO). A tenfold cross‐validation (CV) was repeated ten times (10 × 10‐fold CV) to evaluate the accuracy of the SVM‐LASSO model. Finally, the best model from the 10 × 10‐fold CV was further evaluated using 20 × 5‐ and 50 × 2‐fold CV s. Results: The best SVM‐LASSO model consisted of only two features: the bounding box anterior–posterior dimension (BB _ AP) and the standard deviation of inverse difference moment (SD _ IDM). The BB _ AP measured the extension of a PN in the anterior–posterior direction and was highly correlated (r = 0.94) with the PN size. The SD _ IDM was a texture feature that measured the directional variation of the local homogeneity feature IDM. Univariate analysis showed that both features were statistically significant and discriminative (P = 0.00013 and 0.000038, respectively). PN s with larger BB _ AP or smaller SD _ IDM were more likely malignant. The 10 × 10‐fold CV of the best SVM model using the two features achieved an accuracy of 84.6% and 0.89 AUC. By comparison, Lung‐RADS achieved an accuracy of 72.2% and 0.77 AUC using four features (size, type, calcification, and spiculation). The prediction improvement of SVM‐LASSO comparing to Lung‐RADS was statistically significant (McNemar's test P = 0.026). Lung‐RADS misclassified 19 cases because it was mainly based on PN size, whereas the SVM‐LASSO model correctly classified 10 of these cases by combining a size (BB _ AP) feature and a texture (SD _ IDM) feature. The performance of the SVM‐LASSO model was stable when leaving more patients out with five‐ and twofold CV s (accuracy 84.1% and 81.6%, respectively). Conclusion: We developed an SVM‐LASSO model to predict malignancy of PN s with two CT radiomic features. We demonstrated that the model achieved an accuracy of 84.6%, which was 12.4% higher than Lung‐RADS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.12820

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Choi, W., Oh, J. H., Riyahi, S., Liu, C., Jiang, F., Chen, W., White, C., Rimner, A., Mechalakos, J. G., Deasy, J. O., & Lu, W.
Venue
Medical Physics
Publisher
Wiley
Published
2018-03-12
Volume
45
Issue
4
Pages
1537-1549
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2791069488
Cited by
152
References
8
FWCI
10.55
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.