CoChat

Incorporating human and learned domain knowledge into training deep neural networks: A differentiable dose‐volume histogram and adversarial inspired framework for generating Pareto optimal dose distributions in radiation therapy

Open access
Nguyen, Dan, McBeth, Rafe, Sadeghnejad Barkousaraie, Azar, Bohara, Gyanendra, Shen, Chenyang, Jia, Xun, Jiang, Steve · 2020 · Medical Physics
Cited by 83

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Purpose: We propose a novel domain‐specific loss, which is a differentiable loss function based on the dose‐volume histogram (DVH), and combine it with an adversarial loss for the training of deep neural networks. In this study, we trained a neural network for generating Pareto optimal dose distributions, and evaluate the effects of the domain‐specific loss on the model performance. Methods: In this study, three loss functions — mean squared error (MSE) loss, DVH loss, and adversarial (ADV) loss — were used to train and compare four instances of the neural network model: (a) MSE, (b) MSE + ADV, (c) MSE + DVH, and (d) MSE + DVH+ADV. The data for 70 prostate patients, including the planning target volume (PTV), and the organs at risk (OAR) were acquired as 96 × 96 × 24 dimension arrays at 5 mm 3 voxel size. The dose influence arrays were calculated for 70 prostate patients, using a 7 equidistant coplanar beam setup. Using a scalarized multicriteria optimization for intensity‐modulated radiation therapy, 1200 Pareto surface plans per patient were generated by pseudo‐randomizing the PTV and OAR tradeoff weights. With 70 patients, the total number of plans generated was 84 000 plans. We divided the data into 54 training, 6 validation, and 10 testing patients. Each model was trained for a total of 100,000 iterations, with a batch size of 2. All models used the Adam optimizer, with a learning rate of 1 × 10−3. Results: Training for 100 000 iterations took 1.5 days (MSE), 3.5 days (MSE+ADV), 2.3 days (MSE+DVH), and 3.8 days (MSE+DVH+ADV). After training, the prediction time of each model is 0.052 s. Quantitatively, the MSE+DVH+ADV model had the lowest prediction error of 0.038 (conformation), 0.026 (homogeneity), 0.298 (R50), 1.65% (D95), 2.14% (D98), and 2.43% (D99). The MSE model had the worst prediction error of 0.134 (conformation), 0.041 (homogeneity), 0.520 (R50), 3.91% (D95), 4.33% (D98), and 4.60% (D99). For both the mean dose PTV error and the max dose PTV, Body, Bladder and rectum error, the MSE+DVH+ADV outperformed all other models. Regardless of model, all predictions have an average mean and max dose error <2.8% and 4.2%, respectively. Conclusion: The MSE+DVH+ADV model performed the best in these categories, illustrating the importance of both human and learned domain knowledge. Expert human domain‐specific knowledge can be the largest driver in the performance improvement, and adversarial learning can be used to further capture nuanced attributes in the data. The real‐time prediction capabilities allow for a physician to quickly navigate the tradeoff space for a patient, and produce a dose distribution as a tangible endpoint for the dosimetrist to use for planning. This is expected to considerably reduce the treatment planning time, allowing for clinicians to focus their efforts on the difficult and demanding cases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.13955

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 83

Metadata

Authors
Nguyen, D., McBeth, R., Sadeghnejad Barkousaraie, A., Bohara, G., Shen, C., Jia, X., & Jiang, S.
Venue
Medical Physics
Publisher
Wiley
Published
2019-12-29
Volume
47
Issue
3
Pages
837-849
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2995772144
Cited by
83
References
7
FWCI
7.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Incorporating human and learned domain knowledge into training deep neural networks: A differentiable dose‐volume histogram and adversarial inspired framework for generating Pareto optimal dose distributions in radiation therapy. https://app.cochat.ai/papers/10.1002/mp.13955
The paper
Nguyen, D., McBeth, R., Sadeghnejad Barkousaraie, A., Bohara, G., Shen, C., Jia, X., & Jiang, S. (2020). Incorporating human and learned domain knowledge into training deep neural networks: A differentiable dose‐volume histogram and adversarial inspired framework for generating Pareto optimal dose distributions in radiation therapy. Medical Physics. https://doi.org/10.1002/mp.13955

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.